Magnification characteristic of a +90-diopter double-aspheric fundus examination lens.
نویسندگان
چکیده
PURPOSE To investigate the magnification characteristic of the +90-D double-aspheric fundus examination lens for biomicroscopic measurement of the optic disc. METHODS A calibrated Gullstrand-type model eye adjusted for axial ametropia between -12.5 and +12.6 D was used to measure the change in magnification of the system with refractive error and variation in fundus lens position. A correction factor p (in degrees per millimeter) at different axial ametropias was also calculated. RESULTS The total change in magnification of the system from myopia to hyperopia was -15.1% to +13.7%. When the fundus lens position was altered with respect to the model eye by +/-2 mm under myopic conditions, the change in magnification of the system was -4.8% to +8.1%. In the hyperopic condition the change was -4.8% to +6.0%. The fundus lens exhibited a linear relationship between p and the degree of ametropia of the model eye and a constant relationship between p and ametropia of -5 to +5 D. CONCLUSIONS Axial ametropia has a significant effect on biomicroscopic measurement of the optic disc with the +90-D lens. Therefore, a correction factor (p) was calculated that can be used in calculations for determining true optic disc size. These findings may be important for improving clinical disc biometry.
منابع مشابه
Biomicroscopic examination of the ocular fundus with a +60-diopter lens.
This article describes the design of a +150 dioptre compound lens for biomicroscopic examination of the fundus. To compare the lens with other fundal examination techniques a method is described for measuring the magnification and vertical angle of view of the various examination lenses. By this method the +150 dioptre lens is shown to have an angle of view of 60 degrees. This is similar to tha...
متن کاملDevelopment of an aspheric 22-diopter 50-mm diameter magnifier.
PURPOSE To develop in an interdisciplinary approach between ophthalmology and design areas an ergonomic +22-diopter 50-mm aspheric hand magnifier for low vision. METHODS An aluminum cylinder was cut, processed using a lathe and carved to produce a ring that accommodated a 50-mm aspheric lens, with an external depression not to slide from the holder's fingers. A cylindrical steel bar was cut, ...
متن کاملNew system for fiberoptic-free bimanual vitreous surgery.
OBJECTIVES To describe a new system for fiberoptic-free bimanual vitrectomy and to present the outcome of 37 eyes with preretinal membranes due to diabetic retinopathy or proliferative vitreoretinopathy that underwent surgery using this system. METHODS The system consists of a 40-diopter aspheric field lens suspended from the operating microscope and a prismatic inverting device. The aspheric...
متن کاملCorneal spherical aberration and its impact on choosing an intraocular lens for cataract surgery.
PURPOSE To analyze the post operative results of targeting zero spherical aberration by selecting the best-fit aspheric intraocular lens (IOL), based on preoperative corneal spherical aberration of patients with phacoemulsification surgery. SETTING AlHokama Eye Specialist Center, Riyadh, Saudi Arabia. PERIOD From the 1st of October 2012 until the 10th of April 2013. METHODS Fifty-three ey...
متن کاملCombined pars plana phacofragmentation, vitrectomy, and Artisan lens implantation for traumatic subluxated cataracts.
PURPOSE To report on the outcome of combined pars plana phacofragmentation, vitrectomy, and Artisan lens implantation in the management of subluxated cataracts. METHODS This prospective, interventional, nonrandomized case series included nine eyes of seven consecutive adult patients with traumatic lens subluxation. Pre- and postoperative data (complete manifest refraction, best spectacle-corr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 43 6 شماره
صفحات -
تاریخ انتشار 2002