Development of a test system to evaluate procedures for decontamination of respirators containing viral droplets.
نویسندگان
چکیده
The aim of this study was to develop a test system to evaluate the effectiveness of procedures for decontamination of respirators contaminated with viral droplets. MS2 coliphage was used as a surrogate for pathogenic viruses. A viral droplet test system was constructed, and the size distribution of viral droplets loaded directly onto respirators was characterized using an aerodynamic particle sizer. The sizes ranged from 0.5 to 15 mum, and the sizes of the majority of the droplets were the range from 0.74 to 3.5 mum. The results also showed that the droplet test system generated similar droplet concentrations (particle counts) at different respirator locations. The test system was validated by studying the relative efficiencies of decontamination of sodium hypochlorite (bleach) and UV irradiation with droplets containing MS2 virus on filtering facepiece respirators. It was hypothesized that more potent decontamination treatments would result in corresponding larger decreases in the number of viable viruses recovered from the respirators. Sodium hypochlorite doses of 2.75 to 5.50 mg/liter with a 10-min decontamination period resulted in approximately 3- to 4-log reductions in the level of MS2 coliphage. When higher sodium hypochlorite doses (> or =8.25 mg/liter) were used with the same contact time that was used for the dilute solutions containing 2.75 to 5.50 mg/liter, all MS2 was inactivated. For UV decontamination at a wavelength of 254 nm, an approximately 3-log reduction in the level of MS2 virus was achieved with dose of 4.32 J/cm(2) (3 h of contact time with a UV intensity of 0.4 mW/cm(2)), while with higher doses of UV irradiation (> or =7.20 J/cm(2); UV intensity, 0.4 mW/cm(2); contact times, > or =5 h), all MS2 was inactivated. These findings may lead to development of a standard method to test decontamination of respirators challenged by viral droplets.
منابع مشابه
Effectiveness of three decontamination treatments against influenza virus applied to filtering facepiece respirators.
Filtering facepiece respirators (FFRs) are recommended for use as precautions against airborne pathogenic microorganisms; however, during pandemics demand for FFRs may far exceed availability. Reuse of FFRs following decontamination has been proposed but few reported studies have addressed the feasibility. Concerns regarding biocidal efficacy, respirator performance post decontamination, decont...
متن کاملEffects of relative humidity and spraying medium on UV decontamination of filters loaded with viral aerosols.
Although respirators and filters are designed to prevent the spread of pathogenic aerosols, a stockpile shortage is anticipated during the next flu pandemic. Contact transfer and reaerosolization of collected microbes from used respirators are also a concern. An option to address these potential problems is UV irradiation, which inactivates microbes by dimerizing thymine/uracil in nucleic acids...
متن کاملA pandemic influenza preparedness study: use of energetic methods to decontaminate filtering facepiece respirators contaminated with H1N1 aerosols and droplets.
BACKGROUND A major concern among health care experts is a projected shortage of N95 filtering facepiece respirators (FFRs) during an influenza pandemic. One option for mitigating an FFR shortage is to decontaminate and reuse the devices. Many parameters, including biocidal efficacy, filtration performance, pressure drop, fit, and residual toxicity, must be evaluated to verify the effectiveness ...
متن کاملTraining Manual for Prevention of Covid-19 Disease among Hospital Personnel
Dear Editor In recent days, coronavirus disease (COVID-19) as a viral infection caused by the SARS-Cov-2 virus has become a pandemic disease and has created critical conditions worldwide [1]. According to previous studies on pathogenic viruses associated with acute respiratory distress syndrome, each virus has a specific virulence dose, which it is about 2×103-3×103 viral particles for the inf...
متن کاملStatistical Modeling for Oblique Collision of Nano and Micro Droplets in Plasma Spray Processes
Spreading and coating of nano and micro droplets on solid surfaces is important in a wide variety of applications including plasma spray coating, ink jet printing, DNA synthesis and etc. In spraying processes, most of droplets collide obliquely to the surface. The purpose of this article is to study the distribution of nano and micro droplets spreading when droplets impact at an oblique a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 75 23 شماره
صفحات -
تاریخ انتشار 2009