Randomized Controlled Study of Percutaneous Epidural Neuroplasty Using Racz Catheter and Epidural Steroid Injection in Cervical Disc Disease.

نویسندگان

  • Guy Yeul Ji
  • Chang Hyun Oh
  • Keun Su Won
  • In Bo Han
  • Yoon Ha
  • Dong Ah Shin
  • Keung Nyun Kim
چکیده

BACKGROUND The efficacy of lumbar percutaneous epidural neuroplasty (PEN) as a minimally invasive technique has been relatively well investigated, but the clinical effectiveness of cervical PEN (C-PEN) has yet to be established. OBJECTIVE The purpose of this study was to compare clinical outcomes between C-PEN and cervical epidural steroid injection (C-ESI). STUDY DESIGN Randomized control study. SETTING University hospital center. METHODS Eighty patients with neck pain from single level cervical disease with and without radiculopathy were included in this study. Patients were randomly assigned into 2 groups: C-PEN or C-ESI. Clinical outcomes were assessed according to Neck Disability Index (NDI) score and Visual Analog Scale (VAS) score for arm pain until 12 months after treatment. RESULTS All C-PEN and C-ESI groups showed better NDI recovery and greater reduction in VAS score at postoperative 6 months (P < 0.001). The C-PEN group demonstrated better NDI score at postoperative 6 months than the C-ESI group (P = 0.014), while there were no differences at 2, 4, and 12 months. Additionally, the C-PEN group showed lower VAS scores at all follow-up intervals compared to the C-ESI group (P < 0.050). Symptom relief was sustained for a significantly longer duration in the C-PEN group than in the C-ESI group (23.4 vs. 20.5 weeks, P < 0.001). LIMITATIONS The follow-up period was relatively short with a small sample size, and the grade of cervical disc disease, root compression, and disc degeneration grade were could not considered in this study. CONCLUSIONS C-PEN was superior to C-ESI in terms of better NDI recovery (at 6 months) and greater reduction in VAS score (until 12 months) in treating single level cervical disc herniation. Better outcomes with C-PEN may have been achieved via a more localized selective block in the epidural space closer to the dorsal root ganglion and ventral aspect of the nerve root.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical treatment of a broken neuroplasty catheter in the epidural space: a case report

BACKGROUND Percutaneous epidural neuroplasty with a Racz catheter is widely used to treat radicular pain caused by spinal stenosis or a herniated intervertebral disc. The breakage or shearing of an epidural catheter, particularly a percutaneous epidural neuroplasty catheter, is reported as a rare complication. There has been a controversy over whether surgical removal of a shorn epidural cathet...

متن کامل

Acute Motor Weakness of Opposite Lower Extremity after Percutaneous Epidural Neuroplasty

Recently, percutaneous epidural neuroplasty has become widely used to treat radicular pain caused by spinal stenosis or a herniated intervertebral disc. A 19-year-old female patient suffering from left radicular pain caused by an L4-L5 intervertebral disc herniation underwent percutaneous epidural neuroplasty of the left L5 nerve root using a Racz catheter. After the procedure, the patient comp...

متن کامل

A sheared Racz catheter in cervical epidural space for thirty months: a case report

Percutaneous epidural neuroplasty may lead to complications such as hematoma, infection, epidural abscess, meningitis, hypotension, respiratory depression, urinary and fecal dysfunction, sexual dysfunction and paresthesia. Other technical complications may include shearing or tearing, misplacement, blockage and migration of the catheter. We report a case of a 41-year-old female patient, who und...

متن کامل

Assessment of clinical outcomes of cervical epidural neuroplasty using a Racz-catheter and predictive factors of efficacy in patients with cervical spinal pain.

BACKGROUND Epidural neuroplasty using the Racz catheter has a therapeutic effect in patients with cervical disc herniation and central stenosis who do not respond to fluoroscopically guided epidural injections. OBJECTIVE To evaluate the clinical outcomes of cervical epidural neuroplasty in patients with posterior neck and upper extremity pain and to demonstrate correlations between predictive...

متن کامل

Intracranial hypotension headache caused by a massive cerebrospinal fluid leak successfully treated with a targeted c2 epidural blood patch: a case report.

Cervical epidural steroid injections, administered either interlaminarly or transforaminally, are common injection therapies used in many interventional pain management practices to treat cervicalgia or cervicobrachial pain secondary to spondylosis or intervertebral disc displacement of the cervical spine. Among the risks associated with these procedures are the risk for inadvertent dural punct...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pain physician

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 2016