Jump Power and Force Have Distinct Associations With Cortical Bone Parameters: Findings From a Population Enriched by Individuals With High Bone Mass

نویسندگان

  • Sarah A. Hardcastle
  • Celia L. Gregson
  • Jörn Rittweger
  • Nicola Crabtree
  • Kate Ward
  • Jon H. Tobias
چکیده

CONTEXT Little is known of the relationships between muscle function and bone, based on the recently developed technique of jumping mechanography. OBJECTIVE Our objective was to determine associations between peak ground reaction force and peak power during a 1-legged hopping test and a single 2-legged jump, respectively, and cortical bone parameters. DESIGN AND SETTING This was a cross-sectional observational study in participants from the high bone mass cohort. PARTICIPANTS Participants included 70 males (mean age 58 years) and 119 females (mean age 56 years); high bone mass cases and controls were pooled. MAIN OUTCOME MEASURES Total hip bone mineral density (BMD) (measured by dual-energy x-ray absorptiometry scanning) and mid-tibial peripheral quantitative computed tomography (Stratec XCT2000L). RESULTS Jump power was positively related to hip BMD (standardized β [95% confidence interval]=0.29 [0.07, 0.51], P=.01), but hopping force was not (0.03 [-0.16, 0.22], P=.74) (linear regression analysis adjusted for age, gender, height, and weight). In 113 participants with force and peripheral quantitative computed tomography data, both jump power and hopping force were positively associated with tibial strength strain index (0.26 [0.09, 0.44], P<.01; and 0.24 [0.07, 0.42], P=.01 respectively). Although hopping force was positively associated with bone size (total bone area 0.22 [0.03, 0.42], P=.02), jump power was not (0.10 [-0.10, 0.30], P=.33). In contrast, jump power was inversely associated with endocortical circumference adjusted for periosteal circumference (-0.24 [-0.40, -0.08], P<.01) whereas no association was seen for hopping force (-0.10 [-0.26, 0.07], P=.24). CONCLUSIONS Although power and force are both positively associated with cortical bone strength, distinct mechanisms appear to be involved because power was primarily associated with reduced endocortical expansion (reflected by endocortical circumference adjusted for periosteal circumference, and hip BMD), whereas force was associated with increased periosteal expansion (reflected by total bone area).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Associations of muscle force, power, cross‐sectional muscle area and bone geometry in older UK men

BACKGROUND Ageing is associated with sarcopenia, osteoporosis, and increased fall risk, all of which contribute to increased fracture risk. Mechanically, bone strength adapts in response to forces created by muscle contractions. Adaptations can be through changes in bone size, geometry, and bending strength. Muscle mass is often used as a surrogate for muscle force; however, force can be increa...

متن کامل

Biomechanical Evaluation of Temperature Rising and Applied Force in Controlled Cortical Bone Drilling: An Animal in Vitro Study

Background: The present study was conducted to quantify the relationships between bone drilling process parameters(i.e., feed rate, resting time, exit rate, and drill bit diameter) and drilling outcome parameters (i.e., thrust force andmaximum temperature).Methods: This study utilized 10-cm cortical bovine samples to evaluate the effects of four independent parameters,in...

متن کامل

An investigation of tensile strength of Ti6Al4V titanium screw inside femur bone using finite element and experimental tests

The geometric optimization of orthopedic screws can considerably increase their orthopedic efficiency. Due to the high geometric parameters of orthopedic screws, a finite element simulation is an effective tool for analyzing and forecasting the effect of the parameters on the load-bearing capacity of different types of screws and bones. Thus, in the present study, the tensile strength of a typi...

متن کامل

Relationship between muscle performance and DXA-derived bone parameters in community-dwelling older adults

OBJECTIVES To examine association between muscle strength, jump test performance, muscle mass, bone mineral density (BMD), and bone strength in older adults. METHODS Sixty individuals (55-75 years) participated. Leg press strength and bilateral hip abduction strength were evaluated by one repetition-maximum testing. Jump power (JPow) and jump height (JHt) were assessed by jump test performanc...

متن کامل

مقایسه اثر مواد مختلف سازنده ساختار فلزی روکش بر توزیع تنش پیرامون ایمپلنت با آنالیز اجزاء محدود سه بعدی

Objectives: Despite the high success rate, implant-supported prostheses fail in some cases. Control of the applied forces is an important factor determining the success or failure of implants. Complete understanding of the biomechanical principles in implant-supported prostheses is necessary for offering an appropriate custom-made treatment plan for each patient and reducing the risk of functio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 99  شماره 

صفحات  -

تاریخ انتشار 2014