Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems.

نویسندگان

  • Matheus F da Frota
  • Camila G Espir
  • Fábio L C V Berbert
  • André A F Marques
  • Emílio C Sponchiado-Junior
  • Mario Tanomaru-Filho
  • Lucas F R Garcia
  • Idomeo Bonetti-Filho
چکیده

As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro Evaluation of Cyclic Fatigue Resistance of Reciprocating and Rotary Single-file System

Aim: In vitro study evaluation of the cyclic fatigue resistance of reciprocating and rotary single-file system [Wave One Gold (WOG), Reciproc, Hyflex electrical discharge machining (EDM) file systems] utilizing cyclic fatigue testing device. Materials and methods: Three nickel–titanium rotary systems (Hyflex EDM size #25, 0.06 taper and Reciproc and WOG size #25, 0.06 taper) were used in this s...

متن کامل

Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion: Reciproc versus WaveOne.

INTRODUCTION The use of reciprocating movement was claimed to increase the resistance of nickel-titanium (NiTi) file to fatigue in comparison with continuous rotation. Recently 2 new brands of NiTi files have been marketed for use in a RM mode. The purpose of this study was to compare the cyclic fatigue resistance and torsional resistance of these 2 files, Reciproc and WaveOne. METHODS Cyclic...

متن کامل

Cyclic fatigue and torsional resistance of two new nickel - titanium instruments used in reciprocation motion : Reciproc Versus

The use of reciprocating movement (RM) was claimed to increase the resistance of nickel-titanium (NiTi) file to fatigue in comparison to continuous rotation (CR). Recently two new brands of NiTi file have been marketed for use in a RM mode. The purpose of this study was to compare the cyclic fatigue resistance and torsional resistance of these two files; Reciproc and WaveOne. Cyclic fatigue tes...

متن کامل

Comparison of Cleaning Efficacy and Instrumentation Time of Reciproc and Mtwo Rotary Systems in Primary Molars

Background and Aim: Pulpectomy of primary teeth is commonly performed with hand files and instruments. However, it is a time consuming procedure. Compared to hand files, rotary instrumentation has more advantages. The purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous mo-lars using Reciproc and Mtwo rotary systems. Materials an...

متن کامل

Evaluation of Apical Extrusion of Debris and Irrigant Using Two New Reciprocating and One Continuous Rotation Single File Systems

OBJECTIVE Apical extrusion of debris and irrigants during cleaning and shaping of the root canal is one of the main causes of periapical inflammation and postoperative flare-ups. The purpose of this study was to quantitatively measure the amount of debris and irrigants extruded apically in single rooted canals using two reciprocating and one rotary single file nickel-titanium instrumentation sy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of oral science

دوره 56 4  شماره 

صفحات  -

تاریخ انتشار 2014