Intra-Individual Comparison between 2-D Shear Wave Elastography (GE System) and Virtual Touch Tissue Quantification (Siemens System) in Grading Liver Fibrosis.
نویسندگان
چکیده
Ultrasound-based shear wave elastography (SWE) has recently gained substantial attention for non-invasive assessment of liver fibrosis. The purpose of this study was to perform an intra-individual comparison between 2-D shear wave elastography (2-D-SWE with a GE system) and Virtual Touch Tissue Quantification (VTTQ with a Siemens system) to assess whether these can be used interchangeably to grade fibrosis. Ninety-three patients (51 men, 42 women; mean age, 54 y) with liver disease of various etiologies (hepatitis B virus = 47, hepatitis C virus = 22; alcohol = 6, non-alcoholic steatohepatitis = 5, other = 13) were included. Using published system-specific shear wave speed cutoff values, liver fibrosis was classified into clinically non-significant (F0/F1) and significant (≥F2) fibrosis. Results indicated that intra-modality repeatability was excellent for both techniques (GE 2-D-SWE: intra-class correlation coefficient = 0.89 [0.84-0.93]; VTTQ: intra-class correlation coefficient = 0.90 [0.86-0.93]). Intra-modality classification agreement for fibrosis grading was good to excellent (GE 2-D-SWE: κ = 0.65, VTTQ: κ = 0.82). However, inter-modality agreement for fibrosis grading was only fair (κ = 0.31) using published system-specific shear wave speed cutoff values of fibrosis. In conclusion, although both GE 2-D-SWE and Siemens VTTQ exhibit good to excellent intra-modality repeatability, inter-modality agreement is only fair, suggesting that these should not be used interchangeably.
منابع مشابه
Prospective Comparison of Liver Stiffness Measurements between Two Point Shear Wave Elastography Methods: Virtual Touch Quantification and Elastography Point Quantification
OBJECTIVE To prospectively compare technical success rate and reliable measurements of virtual touch quantification (VTQ) elastography and elastography point quantification (ElastPQ), and to correlate liver stiffness (LS) measurements obtained by the two elastography techniques. MATERIALS AND METHODS Our study included 85 patients, 80 of whom were previously diagnosed with chronic liver disea...
متن کاملProspective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease
OBJECTIVE To assess intra- and inter-observer reproducibility of a new point shear wave elastography technique (pSWE, S-Shearwave, Samsung Medison) and compare its accuracy in assessing liver stiffness (LS) with an established pSWE technique (Virtual Touch Quantification, VTQ). MATERIALS AND METHODS Thirty-three patients were enrolled in this Institutional Review Board-approved prospective st...
متن کاملVirtual Touch Tissue Imaging Quantification Shear Wave Elastography: Prospective Assessment of Cervical Lymph Nodes.
The goal of this study was to prospectively evaluate the diagnostic performance of Virtual Touch tissue imaging quantification (VTIQ) shear wave elastography in the discrimination of benign and malignant cervical lymph nodes in routine clinical practice. Shear wave velocity was analyzed using VTIQ in 100 patients with 100 histologically proven cervical lymph nodes. Diagnostic performance was ev...
متن کاملShear wave elastography with a new reliability indicator
Non-invasive methods for liver stiffness assessment have been introduced over recent years. Of these, two main methods for estimating liver fibrosis using ultrasound elastography have become established in clinical practice: shear wave elastography and quasi-static or strain elastography. Shear waves are waves with a motion perpendicular (lateral) to the direction of the generating force. Shear...
متن کاملVirtual Touch™ Quantification to Diagnose and Monitor Liver Fibrosis in Hepatitis B and Hepatitis C: A NICE Medical Technology Guidance
Virtual Touch™ Quantification (VTq) is a software application used with Siemens Acuson ultrasound scanners to assess the stiffness of liver tissue. The National Institute for Health and Care Excellence (NICE) Medical Technologies Advisory Committee (MTAC) selected VTq for evaluation and invited the company to submit clinical and economic evidence. King's Technology Evaluation Centre, an Externa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasound in medicine & biology
دوره 43 12 شماره
صفحات -
تاریخ انتشار 2017