Highly Sensitive Measurement of Liquid Density in Air Using Suspended Microcapillary Resonators
نویسندگان
چکیده
We report the use of commercially available glass microcapillaries as micromechanical resonators for real-time monitoring of the mass density of a liquid that flows through the capillary. The vibration of a suspended region of the microcapillary is optically detected by measuring the forward scattering of a laser beam. The resonance frequency of the liquid filled microcapillary is measured for liquid binary mixtures of ethanol in water, glycerol in water and Triton in ethanol. The method achieves a detection limit in an air environment of 50 µg/mL that is only five times higher than that obtained with state-of-the-art suspended microchannel resonators encapsulated in vacuum. The method opens the door to novel advances for miniaturized total analysis systems based on microcapillaries with the add-on of mechanical transduction for sensing the rheological properties of the analyzed fluids without the need for vacuum encapsulation of the resonators.
منابع مشابه
Highly Selective Lowpass Filter with Wide Stopband in Suspended Stripline Technology for Millimeter-wave Diplexer Applications
This paper presents a low loss and high selective lowpass filter which is implemented using suspended stripline (SSL) technology. The proposed structure is comprised of a 13th order generalized Chebyshev lowpass filter which enjoys integrated waveguide-to-SSL transitions. This filter is designed and fabricated to be used as lowpass channel of a U-band diplexer employed in frontend of a U-band d...
متن کاملPulled microcapillary tube resonators with electrical readout for mass sensing applications
This paper reports a microfabrication-free approach to make hollow channel mass sensors by pulling a glass capillary and suspending it on top of a machined jig. A part of the pulled section makes simple contact with an actuation node and a quartz tuning fork (QTF) which acts as a sensing node. The two nodes define a pulled micro capillary tube resonator (PμTR) simply supported at two contacts. ...
متن کاملExperimental measurement and model analysis of damping effect in nanoscale mechanical beam resonators in air
The damping effect in the nanoscale mechanical beam resonators operated under ambient conditions was studied. Experimental measurement of the viscous air damping in the nanowire cantilever resonators was carried out using the electric-field-induced resonance method; and a theoretical model, which accounts for the effects of dimension and material property of the nanowires and the air viscosity ...
متن کاملStudy of Suspended Air Particles and Health Risk Assessment of Exposure to PM10 and PM2.5 in One of the Textile Industries
Background & objectives: Work-related illnesses account for a large number of social problems. According to occupational therapists, occupational diseases are considered as life-threatening factors for workers. The aim of this study was to measure air pollution to suspended particles and to assess the health risk of PM2.5 and PM10 exposure in the textile industry. Methods: This analytical-cros...
متن کاملComparison of Directly Suspended Drop Microextraction with Dispersive Liquid-liquid Microextraction Method for Extraction of Doxepin in Water and Biological Samples Prior to UV-Vis Spectrophotometer
The present research describes the use of directly suspended drop microextraction and air-assisted dispersive liquid-liquid microextraction method coupled with UV-Vis spectrophotometer for the analysis of doxepin in water and biological samples. Several important parameters which influence the extraction efficiencies of these two microextraction methods, such as the kind of extracting solven...
متن کامل