Sevoflurane‐induced isoelectric EEG and burst suppression: differential and antagonistic effect of added nitrous oxide
نویسندگان
چکیده
The objective of this study was to investigate whether nitrous oxide influenced the ED50 of sevoflurane for induction of isoelectric electroencephalogram (ED50isoelectric ) differently from its influence on the ED50 of sevoflurane for electroencephalogram burst suppression (ED50burst ). In a prospective, randomised, double-blind, parallel group, up-down sequential allocation study, 77 ASA physical status 1 and 2 patients received sevoflurane induction and, after tracheal intubation, were randomly allocated to receive sevoflurane with either 40% oxygen in air (control group) or 60% nitrous oxide in oxygen mixture (nitrous group). The ED50isoelectric in the two groups was determined using Dixon's up and down method, starting at 2.5% with 0.2% step size of end-tidal sevoflurane. The electroencephalogram was considered as isoelectric when a burst suppression ratio of 100% lasted > 1 min. The subsequent concentrations of sevoflurane administered were determined by the presence or absence of isoelectric electroencephalogram in the previous patient in the same group. The ED50isoelectric in the nitrous group 4.08 (95%CI, 3.95-4.38)% was significantly higher than that in the control group 3.68 (95%CI, 3.50-3.78)% (p < 0.0001). The values for ED50burst were 3.05 (95%CI, 2.66-3.90)% and 3.02 (95%CI, 3.00-3.05)% in nitrous group and control group, respectively (p = 0.52). The addition of 60% nitrous oxide increases ED50isoelectric , but not the ED50burst of sevoflurane. Neither result indicates an additive effect of anaesthetic agents, as might be expected, and possible reasons for this are discussed.
منابع مشابه
Effects of nitrous oxide on spectral entropy of the EEG during surgery under balanced anaesthesia with sufentanil and sevoflurane.
BACKGROUND Spectral entropy of the electroencephalogram (EEG) has been proposed to monitor anaesthetic depth. We investigated the effect of nitrous oxide on response (RE) and state entropy (SE) of the EEG during lumbar disc surgery under anaesthesia with sufentanil and sevoflurane. METHODS In an open study, anaesthesia was induced with propofol and sufentanil, and maintained with 2% end-tidal...
متن کاملMinimal alveolar concentration of sevoflurane for induction of isoelectric electroencephalogram in middle-aged adults.
BACKGROUND We determined the minimal alveolar concentration (MAC) of sevoflurane inducing an isoelectric EEG in 50% of adult subjects (MACie). METHODS We included 31 middle-aged subjects; 30 subjects finished the study protocol and received sevoflurane at preselected concentrations according to a modified Dixon 'up-and-down' design starting at 1.7 vol% with 0.2 vol% steps size. General anaest...
متن کاملNitrous oxide-mediated activation of the EEG during isoflurane anaesthesia in patients.
We have studied the effects of nitrous oxide on EEG burst suppression patterns during stable isoflurane anaesthesia in 13 ASA I patients. After induction of anaesthesia with propofol, the concentration of isoflurane was increased with continuous EEG monitoring to burst suppression level (mean end-tidal concentration of isoflurane, 1.7 (SD 0.2)%), and kept constant during the study. During surge...
متن کاملNitrous oxide-induced slow and delta oscillations
OBJECTIVES Switching from maintenance of general anesthesia with an ether anesthetic to maintenance with high-dose (concentration >50% and total gas flow rate >4 liters per minute) nitrous oxide is a common practice used to facilitate emergence from general anesthesia. The transition from the ether anesthetic to nitrous oxide is associated with a switch in the putative mechanisms and sites of a...
متن کاملBurst suppression or isoelectric encephalogram for cerebral protection: evidence from metabolic suppression studies.
Metabolic suppression may have a role in cerebral protection. It is often assumed that the cerebral metabolic and protective effects of qualitative burst suppression are similar to those of the isoelectric encephalogram (EEG). We have examined the effect of different degrees of EEG suppression on blood flow and oxygen difference during general anaesthesia. We studied 11 patients undergoing gene...