Continuous-flow IRMS technique for determining the O excess of CO2 using complete oxygen isotope exchange with cerium oxide

نویسندگان

  • D. J. Mrozek
  • C. van der Veen
  • M. Kliphuis
  • J. Kaiser
  • A. A. Wiegel
  • T. Röckmann
چکیده

This paper presents an analytical system for analysis of all single substituted isotopologues (COO, COO, COO) in nanomolar quantities of CO2 extracted from stratospheric air samples. CO2 is separated from bulk air by gas chromatography and CO2 isotope ratio measurements (ion masses 45 / 44 and 46 / 44) are performed using isotope ratio mass spectrometry (IRMS). The O excess (1O) is derived from isotope measurements on two different CO2 aliquots: unmodified CO2 and CO2 after complete oxygen isotope exchange with cerium oxide (CeO2) at 700 C. Thus, a single measurement of 1O requires two injections of 1 mL of air with a CO2 mole fraction of 390 μmol mol at 293 K and 1 bar pressure (corresponding to 16 nmol CO2 each). The required sample size (including flushing) is 2.7 mL of air. A single analysis (one pair of injections) takes 15 minutes. The analytical system is fully automated for unattended measurements over several days. The standard deviation of the O excess analysis is 1.7 ‰. Multiple measurements on an air sample reduce the measurement uncertainty, as expected for the statistical standard error. Thus, the uncertainty for a group of 10 measurements is 0.58 ‰ for 1O in 2.5 h of analysis. 100 repeat analyses of one air sample decrease the standard error to 0.20 ‰. The instrument performance was demonstrated by measuring CO2 on stratospheric air samples obtained during the EU project RECONCILE with the high-altitude aircraft Geophysica. The precision for RECONCILE data is 0.03 ‰ (1σ) for δC, 0.07 ‰ (1σ) for δO and 0.55 ‰ (1σ) for δO for a sample of 10 measurements. This is sufficient to examine stratospheric enrichments, which at altitude 33 km go up to 12 ‰ for δO and up to 8 ‰ for δO with respect to tropospheric CO2 : δ O ≈ 21 ‰ Vienna Standard Mean Ocean Water (VSMOW), δO ≈ 41 ‰ VSMOW (Lämmerzahl et al., 2002). The samples measured with our analytical technique agree with available data for stratospheric CO2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Can we use the CO2 concentrations determined by continuous-flow isotope ratio mass spectrometry from small samples for the Keeling plot approach?

A common method to estimate the carbon isotopic composition of soil-respired air is to use Keeling plots (delta(13)C versus 1/CO2 concentration). This approach requires the precise determination of both CO2 concentration ([CO2]), usually measured with an infrared gas analyser (IRGA) in the field, and the analysis of delta(13)C by isotope ratio mass spectrometry (IRMS) in the laboratory. We meas...

متن کامل

Continuous-flow isotope ratio mass spectrometry method for carbon and hydrogen isotope measurements on atmospheric methane

We describe a continuous-flow isotope ratio mass spectrometry (CF-IRMS) technique for high-precision δD and δ13C measurements of atmospheric methane on 40 mL air samples. CH4 is separated from other air components by utilizing purely physical processes based on temperature, time and mechanical valve switching. Chemical agents are avoided. Trace amounts of interfering compounds can be separated ...

متن کامل

Field-based stable isotope analysis of carbon dioxide by mid-infrared laser spectroscopy for carbon capture and storage monitoring.

A newly developed isotope ratio laser spectrometer for CO2 analyses has been tested during a tracer experiment at the Ketzin pilot site (northern Germany) for CO2 storage. For the experiment, 500 tons of CO2 from a natural CO2 reservoir was injected in supercritical state into the reservoir. The carbon stable isotope value (δ(13)C) of injected CO2 was significantly different from background val...

متن کامل

Measurement of δ18O and δ2H values of fluid inclusion water in speleothems using cavity ring-down spectroscopy compared with isotope ratio mass spectrometry.

RATIONALE The hydrogen and oxygen isotopic analyses (δ(2)H and δ(18)O values) of water trapped within speleothem carbonate (fluid inclusions) have traditionally been conducted utilizing dual-inlet isotope ratio mass spectrometry (IRMS) or continuous-flow (CF)-IRMS methods. The application of cavity ring-down spectroscopy (CRDS) to the δ(2)H and δ(18)O analysis of water in fluid inclusions has b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015