Comparison of the NovaSom QSGe, a new sleep apnea home-diagnostic system, and polysomnography

نویسندگان

  • James A. Reichert
  • Daniel A. Bloch
  • Elizabeth Cundiff
  • Bernhard A. Votteri
چکیده

Background: Obstructive sleep apnea (OSA) is a serious, common, and underdiagnosed disorder that challenges health care resources. While polysomnography (PSG) represents the standard diagnostic test for OSA, portable devices provide an alternative diagnostic tool when issues of cost, time, geographic availability, or other constraints pose impediments to in-lab testing. This study compares the NovaSom QSGe, a new sleep apnea home diagnostic system, to PSG both in the laboratory and in the home. Methods: Fifty-one consecutive adults referred to the sleep lab for suspicion of OSA underwent one night of in-lab, simultaneous recording of PSG and NovaSom QSG in addition to using the NovaSom QSG at home for three nights. Two separate comparisons were made using the apnea–hypopnea index (AHI): in-lab PSG to in-lab NovaSom QSG and in-lab PSG to home NovaSom QSG. Results: Using a clinical cut-off of AHI 1⁄4 15, the sensitivity and specificity of the in-lab NovaSom QSG vs. PSG were 95% and 91%, respectively. For home NovaSom QSG vs. in-lab PSG, the sensitivity was 91% and specificity was 83%. The intra-class correlation coefficient for the agreement between three separate nights of NovaSom QSG home data was 0.88. Conclusions: In a patient population suspected of having OSA, the NovaSom QSG demonstrated acceptable sensitivity and specificity both in the lab and self-administered in the home, when compared to PSG. q 2003 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the NovaSom QSG, a new sleep apnea home-diagnostic system, and polysomnography.

BACKGROUND Obstructive sleep apnea (OSA) is a serious, common, and underdiagnosed disorder that challenges health care resources. While polysomnography (PSG) represents the standard diagnostic test for OSA, portable devices provide an alternative diagnostic tool when issues of cost, time, geographic availability, or other constraints pose impediments to in-lab testing. This study compares the N...

متن کامل

Description and validation of the apnea risk evaluation system: a novel method to diagnose sleep apnea-hypopnea in the home.

STUDY OBJECTIVES To evaluate the accuracy and practicality of the Apnea Risk Evaluation System (ARES; Advanced Brain Monitoring; Carlsbad, CA), a limited-channel system for diagnosing sleep apnea/hypopnea in the home. DESIGN Prospective randomized study with blinded analysis. SETTINGS Two independent, community-based, sleep-disorders centers and the participants' homes. PARTICIPANTS Two h...

متن کامل

Apert Syndrome with Obstructive Sleep Apnea: A Case Report

Apert syndrome is a rare kind of craniosynostosis which is identified with fusion of cranial sutures during prematurity period and causes physical and intellectual disorders in younger ages. These patients may show symptoms of obstructive sleep apnea due to abnormal craniofacial shape. This article introduces a patient with Apert syndrome, with apnea symptoms, cyanosis, snoring, restlessness, n...

متن کامل

Clinical validation of the Bedbugg in detection of obstructive sleep apnea.

OBJECTIVE To validate the accuracy of the Bedbugg, a new home monitoring device for diagnosis of obstructive sleep apnea. STUDY DESIGN AND SETTING Simultaneous sleep monitoring was performed by formal polysomnography and by Bedbugg. Monitoring was performed in a university sleep center in 42 subjects who had previously been scheduled for polysomnography. RESULTS The correlation for the apne...

متن کامل

Evaluation of a portable device for diagnosing the sleep apnoea/hypopnoea syndrome.

Waiting times for hospital-based monitoring of the obstructive sleep apnoea/hypopnoea syndrome (OSAHS) are rising. This study tested whether Embletta, a new portable device, may accurately diagnose OSAHS at home. A synchronous comparison to polysomnography was performed in 40 patients and a comparison of home Embletta studies with in-laboratory polysomnography was performed in 61 patients. In t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003