Effects of azotemia on results of the boronate-agarose affinity and ion-exchange methods for glycated hemoglobin.
نویسندگان
چکیده
We evaluated the effect of azotemia on results for glycated hemoglobin as measured by a boronate-agarose affinity method and an ion-exchange chromatographic procedure with saline preincubation and found a good correlation. However, values for glycated hemoglobin in samples from nondiabetic patients with various degrees of azotemia were consistently higher with the ion-exchange column procedure (mean, 8.5%) than with the boronate affinity method (mean, 6.2%). The latter method may thus be preferred for monitoring glycated hemoglobin in diabetic patients with impaired renal function.
منابع مشابه
Effects of hemoglobin C and S traits on the results of 14 commercial glycated hemoglobin assays.
Glycated hemoglobin is widely used in the management of diabetes mellitus. At least 300,000 Americans with diabetes mellitus have the hemoglobin (Hb) C or S trait. The accuracy of HbA1c methods can be adversely affected by the presence of these traits. We evaluated the effects of HbC and HbS traits on the results of 14 commercial HbA1c methods that use boronate affinity, enzymatic, immunoassay,...
متن کاملSurveying the Effect of Hydroalcoholic Extract of Allium hirtifolium on Glycated Hemoglobin Formation in In-vitro Condition
Background & Objectives: Non enzymatic glycation is a reaction that occurs between reducing sugars and amino groups of proteins. Advanced Glycation End-products (AGE) have been accounted for principal biological processes like aging and pathogenesis of some diseases. Accumulation of AGE during hyperglycemia can cause structural and functional changes of long-lived proteins. Therefore, it will...
متن کاملLiquid-chromatographic determination of acetylated hemoglobin.
In this liquid-chromatographic assay for acetylated hemoglobin in human blood, glycated hemoglobins in hemolysates are first removed by affinity chromatography on boronate-agarose columns. Acetylated hemoglobin in the nonretained fraction is determined by cation-exchange chromatography. The absorbance of the effluent is monitored at 415 nm. The mean within-assay CV was 8.5%, the between-assay C...
متن کاملAffinity binding assay of glycohemoglobin by two-dimensional centrifugation referenced to hemoglobin A1c.
We describe an automated assay of glycohemoglobin performed with the Abbott Vision analyzer. The assay is based on batch affinity-extraction with 3-aminophenylboronic acid-derivatized agarose beads. Reagents are packaged in a disposable test pack. Whole-blood specimens are hemolyzed with saponin within a glass capillary tube inserted into the test pack. The sample is automatically diluted with,...
متن کاملWhat is hemoglobin A1c? An analysis of glycated hemoglobins by electrospray ionization mass spectrometry.
Hemoglobin A1c (HbA1c) is a stable minor Hb variant formed in vivo by posttranslational modification by glucose, originally identified by using cation exchange chromatography, and containing primarily glycated N-terminal beta-chains. However, the structure(s) of the quantified species has not been elucidated, and the available methods lack a reference standard. We used electrospray ionization m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 30 6 شماره
صفحات -
تاریخ انتشار 1984