Enhanced Linear-array Photoacoustic Beamforming using Modified Coherence Factor

نویسندگان

  • Moein Mozaffarzadeh
  • Mohammad Mehrmohammadi
  • Bahador Makkiabadi
چکیده

Photoacoustic imaging (PAI) is a promising medical imaging modality providing the spatial resolution of ultrasound imaging and the contrast of optical imaging. For linear-array PAI, a beamformer can be used as the reconstruction algorithm. Delay-and-sum (DAS) is the most prevalent beamforming algorithm in PAI. However, using DAS beamformer leads to low-resolution images as well as high sidelobes due to nondesired contribution of off-axis signals. Coherence factor (CF) is a weighting method in which each pixel of the reconstructed image is weighted, based on the spatial spectrum of the aperture, to mainly improve the contrast. We demonstrate that the numerator of the formula of CF contains a DAS algebra and propose the use of a delay-multiply-and-sum beamformer instead of the available DAS on the numerator. The proposed weighting technique, modified CF (MCF), has been evaluated numerically and experimentally compared to CF. It was shown that MCF leads to lower sidelobes and better detectable targets. The quantitative results of the experiment (using wire targets) show that MCF leads to for about 45% and 40% improvement, in comparison with CF, in the terms of signal-to-noise ratio and full-width-half-maximum, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

B-Mode Photoacoustic Imaging using Linear Array: Numerical Study for Forward-Backward Minimum Variance Beamformer Combined with Delay-Multiply-and-Sum

Photoacoustic imaging (PAI) is a promising medical imaging modality which provides the resolution of Ultrasound (US) and the contrast of Optical imaging modalities. One of the most important challenges in PAI is image formation, especially in the case that a linear-array US transducer is used for data acquisition. This is due to the fact that in the linear-array scenario, there is only 60 degre...

متن کامل

Optimization of Array Factor in Linear Arrays Using Modified Genetic Algorithm

The array factor (sidelobe level, SLL) of a linear array is optimized using modified continuous genetic algorithms in this work. The amplitudes and phases of the currents as well as the separation of the antennas are all taken as variables to be controlled. The results of the design using modified GA versions are compared with other methods. Two design problems were studied using several contin...

متن کامل

TDL-based Wideband Beamforming for Radio Sources Close to the Array Endfire

Uniform linear array (ULA)-based tapped-delay line (TDL) structure has good performance metrics when the signal sources are located at the middle angles. It offers poor performance when the signal sources are close to the array endfire. In this paper, a new approach is proposed which offers higher performance and desired beamforming on TDL structure when the wideband uncorrelated radio sources ...

متن کامل

ast 3 - D dark - field reflection - mode photoacoustic icroscopy in vivo with a 30 - MHz ultrasound inear array

ihong V. Wang ashington University in St. Louis ptical Imaging Laboratory epartment of Biomedical Engineering t. Louis, Missouri 63130 -mail: [email protected] Abstract. We present an in vivo dark-field reflection-mode photoacoustic microscopy system that performs cross-sectional B-scan imaging at 50 Hz with real-time beamforming and 3-D imaging consisting of 166 B-scan frames at 1 Hz wit...

متن کامل

Photoacoustic Imaging using Combination of Eigenspace-Based Minimum Variance and Delay-Multiply-and-Sum Beamformers: Simulation Study

Delay and Sum (DAS), as the most common beamforming algorithm in Photoacoustic Imaging (PAI), having a simple implementation, results in a low-quality image. Delay Multiply and Sum (DMAS) was introduced to improve the quality of the reconstructed images using DAS. However, the resolution improvement is now well enough compared to high resolution adaptive reconstruction methods such as Eigenspac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 23 2  شماره 

صفحات  -

تاریخ انتشار 2018