Vitreous flow rates through dual pneumatic cutters: effects of duty cycle and cut rate
نویسنده
چکیده
PURPOSE We aimed to investigate effects of instrument settings on porcine vitreous flow rates through dual pneumatic high-speed vitrectomy probes. METHODS The CONSTELLATION(®) Vision System was tested with 250, 450, and 650 mmHg of vacuum using six ULTRAVIT(®) vitrectomy probes of each diameter (25+(®), 25, 23, and 20 gauge) operated from 500 cuts per minute (cpm) up to 5,000 cpm. Duty cycle modes tested included biased open, 50/50, and biased closed. Flow rates were calculated by assessing the change in weight of porcine eyes during vitreous aspiration. Volumetric flow rate was measured with a computer-connected electronic scale. RESULTS At lower cut rates, the biased open mode produced higher flow than did the 50/50 mode, which produced higher flow than did the biased closed mode. In the biased closed and 50/50 modes, vitreous flow rates tended to increase with increasing cut rate. Vitreous flow rates in the biased open duty cycle mode remained relatively constant across cut rates. CONCLUSION Vitreous flow rates through dual pneumatic vitrectomy probes could be manipulated by changing the duty cycle modes on the vitrectomy system. Differences in duty cycle behavior suggest that high-speed cut rates of 5,000 cpm may optimize vitreous aspiration.
منابع مشابه
Fluidics in a dual pneumatic ultra high-speed vitreous cutter system.
BACKGROUND Dual pneumatic systems use two separate air line tubes to open and close the cutter and can achieve high cut rates. The purpose of this study is to evaluate the influence of gauge size, cut rate and aspiration on the flow rate performance of ultra high-speed cutters operated with a commercially available dual pneumatic vitrectomy system. METHODS Analysis of a high-speed video was u...
متن کاملPorcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute
PURPOSE To evaluate the impact of high-speed cut rates (up to 7500 cuts per minute [cpm]) on vitreous flow through various gauge probes. METHODS An open-sky vitrectomy technique was performed on porcine eyes using the CONSTELLATION Vision System with three different gauges of dual-pneumatic probes (27+-, 25+-, and 23-gauge UltraVit probes; n = 5 for each gauge). Flow rate was calculated by La...
متن کاملPerformance Comparison of High-Speed Dual-Pneumatic Vitrectomy Cutters during Simulated Vitrectomy with Balanced Salt Solution.
PURPOSE To measure flow rate of balanced salt solution and IOP during simulated vitrectomy using two sets of high-speed dual-pneumatic probes. METHODS A closed-model eye system measured IOP and flow rate of a balanced salt solution through infusion cannula. The Constellation Vision System was tested with two sets of high-speed dual-pneumatic probes (UltraVit 23-gauge and enhanced 25+-gauge 50...
متن کاملHydraulic Resistance of Vitreous Cutters: The Impact of Blade Design and Cut Rate
PURPOSE To measure the hydraulic resistance (HR) of vitreous cutters equipped with a Regular guillotine Blade (RB) or double edge blade (DEB) at cut rates comprised between 0 and 12,000 cuts per minute (CPM) and compare it with vitreous fragment size. This was an in vitro experimental study; in vivo HR measure and vitreous sampling. METHODS HR, defined as aspiration pressure/flow rate, was me...
متن کاملVitreoretinal instruments: vitrectomy cutters, endoillumination and wide-angle viewing systems
There have been many advances in vitreoretinal surgery since Machemer introduced the concept of pars plana vitrectomy, in 1971. Of particular interest are the changes in the vitrectomy cutters, their fluidics interaction, the wide-angle viewing systems and the evolution of endoillumination through the past decade and notably in the last few years. The indications of 27-gauge surgery have expand...
متن کامل