Changes in pleth variability index and detection of hypotension during spinal anaesthesia for caesarean section.
نویسندگان
چکیده
Background: Hypotension occurs commonly during caesarean section under spinal anaesthesia. As the onset may be rapid, it may fail to be detected by non-invasive blood pressure (BP) measurement in a timely fashion. Pulse oximeters can continuously and non-invasively measure tissue perfusion (perfusion index (PI)) and its variation with the respiratory cycle (pleth variability index (PVI)). As with stroke volume variation, PVI predicts fluid responsiveness in mechanically ventilated patients with a high degree of sensitivity and specificity. Whilst there have been very few studies in spontaneously breathing patients, a volunteer study revealed that PVI decreased with straight leg raising. As stroke volume variation is known to increase during spinal anaesthesia, we hypothesized that this would also be the case for PVI and that this rise could be used to identify the onset of hypotension.
منابع مشابه
The predictive ability of non-invasive haemodynamic parameters for hypotension during caesarean section: a prospective observational study.
Spinal anaesthesia for caesarean section induces hypotension, which may cause severe adverse effects. Our goal was to determine whether hypotension could be predicted by pulse oximetry parameters, such as the perfusion index and pleth variability index, heart rate, ratio of low-frequency to high-frequency components of heart rate variability, and entropy of heart rate variability, measured befo...
متن کاملPerfusion index derived from a pulse oximeter can predict the incidence of hypotension during spinal anaesthesia for Caesarean delivery.
BACKGROUND Hypotension during spinal anaesthesia for Caesarean delivery is a result of decreased vascular resistance due to sympathetic blockade and decreased cardiac output due to blood pooling in blocked areas of the body. Change in baseline peripheral vascular tone due to pregnancy may affect the degree of such hypotension. The perfusion index (PI) derived from a pulse oximeter has been used...
متن کاملVentilatory management of severe acute respiratory failure for Y2K.
condition of mother and infant at cesarean section. Anesth Analg 1969; 48:986–93 8. Clark RB, Thompson DS, Thompson CH: Prevention of spinal hypotension associated with cesarean section. ANESTHESIOLOGY 1976; 45:670–4 9. Russell IF: Effect of posture during the induction of subarachnoid analgesia for caesarean section. Right v left lateral. Br J Anaesth 1987; 59:342–6 10. Norris MC: Hypotension ...
متن کاملمقایسه اثر بوپیواکائین و لیدوکائین اینتراتکال بر میزان بروز افت فشار خون و تهوع واستفراغ در سزارین
Aim and Background: Hypotension and nausea are common side effects during spinal anesthesia. This study compared the incidence of hypotension and nausea-vomiting induced by bupivacaine and lidocaine in parturients undergoing caesarean section under spinal anaesthesia. Methods and Materials: In this...
متن کاملEffect of crystalloid and colloid preloading on uteroplacental and maternal haemodynamic state during spinal anaesthesia for caesarean section.
We have studied the effects of crystalloid 1 litre (lactated Ringer's) or colloid 0.5 litre (hydroxyethyl starch) preloading in 26 healthy parturients undergoing elective Caesarean section under spinal anaesthesia. Maternal placental uterine artery circulation was measured using a pulsed colour Doppler technique with simultaneous measurement of maternal haemodynamics. A high incidence of matern...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- International journal of obstetric anesthesia
دوره 24 4 شماره
صفحات -
تاریخ انتشار 2015