Quantitative comparison of anti-fading mounting media for confocal laser scanning microscopy.

نویسندگان

  • M Ono
  • T Murakami
  • A Kudo
  • M Isshiki
  • H Sawada
  • A Segawa
چکیده

Fading is one of the major obstacles to reliable observation in fluorescence microscopy. Using a confocal laser scanning microscope (CLSM) coupled to a computer, we quantitatively measured fading of fluorescence to formulate an equation, evaluated the anti-fading ability of several anti-fading media, and restored the faded images to the original level according to this equation. NIH 3T3 cells were stained with fluorescein isothiocyanate (FITC)-phalloidin, mounted with several commercial and homemade anti-fade media, and observed with CLSM under repeated illumination. With any mounting medium, attenuation of fluorescence intensity at a certain pixel occurred stepwise and the decrease was proportional to the intensity of the previous scan. From these results, we formulated an equation that has three coefficients: anti-fading factor (A), indicating the ability to retard fading; fluorescent intensity at the first scan (EM(1)); and background fluorescence (B). The fluorescent intensity at a certain point following nth scan is given as EM(n) = EM(1) * A ((n-1)). This equation was available for restoring faded images to their original states, even after the image had faded to only 60% of its original intensity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An update: improvements in imaging perfluorocarbon-mounted plant leaves with implications for studies of plant pathology, physiology, development and cell biology

Plant leaves are optically complex, which makes them difficult to image by light microscopy. Careful sample preparation is therefore required to enable researchers to maximize the information gained from advances in fluorescent protein labeling, cell dyes and innovations in microscope technologies and techniques. We have previously shown that mounting leaves in the non-toxic, non-fluorescent pe...

متن کامل

Variations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy

Background  To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...

متن کامل

Improving Axial Resolution in Confocal Microscopy with New High Refractive Index Mounting Media

Resolution, high signal intensity and elevated signal to noise ratio (SNR) are key issues for biologists who aim at studying the localisation of biological structures at the cellular and subcellular levels using confocal microscopy. The resolution required to separate sub-cellular biological structures is often near to the resolving power of the microscope. When optimally used, confocal microsc...

متن کامل

Optimal clearing and mounting media for confocal microscopy of thick specimens

Sample preparation for confocal microscopy typically involves fixing and staining, followed by clearing and mounting. Clearing involves treatment with solvent to dissolve lipids and other structures that cause light scattering and reduce the ability to image through thick specimens. Mounting involves transfer of the specimen into a medium which matches the refractive index the objective is desi...

متن کامل

The development of exo-erythrocytic schizonts of Plasmodium berghei in vitro from gamma-irradiated and non-irradiated sporozoites: a study using confocal laser scanning microscopy.

Confocal scanning laser microscopy has been used to study the distribution of antigens expressed by the liver stages of Plasmodium berghei in cultured hepatoma cells. The 3-dimensional images obtained of intact parasites clearly show complex patterns of antigen expression not apparent when using conventional IFAT or immunoelectron microscopy. A liver-stage specific antigen (Pbl 1) was shown to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society

دوره 49 3  شماره 

صفحات  -

تاریخ انتشار 2001