Variations in skin dose associated with linac bed material at 6 MV x-ray energy.

نویسندگان

  • Martin J Butso
  • Tsang Cheung
  • Peter K N Yu
  • Belinda Webb
چکیده

Treatment with radiotherapy x-rays at 6 MV energy produces a build-up effect whereby a smaller dose is delivered to the patient's skin compared to the tumour dose. With anterior fields, no material is normally placed over the patient's skin, thus providing the maximum skin sparing possible with the beam configuration used. A posterior beam normally passes through the treatment couch top and increases the dose delivered to the patient's skin. Both the Mylar sheeting and the support ribbing material produce a significant increase in skin dose. Measurements at 6 MV have shown that the basal cell layer dose can be increased by up to 51% of maximum dose with a carbon fibre/Mylar couch and by 28% for a tennis string/Mylar couch when compared to anterior beams. These values are associated with the position of the carbon fibre or tennis string ribbing. Dermal layer doses are increased by up to 30 and 24% of maximum dose for carbon fibre and tennis string, respectively. These values include a combination of dose due to the support ribbing and the Mylar sheeting. Due to the variability in patient positioning on the couch top, these increases would be spread out over the skin surface producing an average increase per unit area at the basal layer of up to 32 and 20% of the maximum, respectively, for carbon fibre and tennis string couch tops and 21 and 12% at the dermal layer compared to dose at Dmax.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of Secondary Skin Cancer Risk Due To Electron Contamination in 18-MV LINAC-Based Prostate Radiotherapy

Introduction Accurate estimation of the skin-absorbed dose in external radiation therapy is essential to estimating the probability of secondary carcinogenesis induction Materials and Methods Electron contamination in prostate radiotherapy was investigated using the Monte Carlo (MC) code calculation. In addition, field size dependence of the skin dose was assessed. Excess cancer risk induced by...

متن کامل

Evaluation of the dose perturbation around gold and steel fiducial markers in a medical linac through Geant4 Monte Carlo simulation.

OBJECTIVE Purpose of this work was to study the dose perturbation within the target volume of a external MV radiation therapy when using metal fiducials. METHODS We developed a Monte Carlo simulation in Geant4 of a cylindrical fiducial made either of gold or of steel and simulated the photon irradiation beam originating from a medical Linac operating at 6, 10 or 15 MV. For each energy, two di...

متن کامل

Evaluation of Tumor Control and Normal Tissue Complication Probability in Head and Neck Cancers with Different Sources of Radiation: A Comparative Study

Introduction: The ultimate goal of radiation treatment planning is to yield a high tumor control probability (TCP) with a low normal tissue complication probability (NTCP). Historically  dose volume histogram (DVH) with only volumetric dose distribution was utilized as a popular tool for plan evaluation  hence present study aimed to compare the radiobiological effectiveness of the cobalt-60 (Co...

متن کامل

Investigation of LINAC Structural Effects on Photoneutron Specified Parameters Using FLUKA code

Introduction: The utilization of high-energy photons in the medical linear accelerator can lead to photoneutron production. This study aimed to evaluate the effect of the physical components of the head, including flattening filter (FF) andmultileaf collimator (MLC), as well as the dependence of therapeutic field size on the photoneutron spectrum, dose, and flux. <str...

متن کامل

Comparison of conventional and 3D conformal treatments using linac energies for prostate cancer

Background: To evaluate the dosimetric difference between conventional and three-dimensional conformal Radiotherapy (3D-CRT) using 6 and 18 MV X-ray photons. Materials and Methods: Computed tomography scans of 26 pelvic patients were acquired and transferred to the 3D treatment planning system. For each patient, 8 Conventional plans (3, 4, 5 and 6 Fields) and one 3D-CRT plan were prep...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 47 1  شماره 

صفحات  -

تاریخ انتشار 2002