Optimized method for determination of 16 FDA polycyclic aromatic hydrocarbons (PAHs) in mainstream cigarette smoke by gas chromatography–mass spectrometry
نویسندگان
چکیده
A gas chromatography-mass spectrometry (GC-MS) method was validated for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) from the FDA list of 93 harmful or potentially harmful constituents of mainstream cigarette smoke (MCS). Target analytes were extracted from total particulate matter using accelerated solvent extraction with a toluene/ethanol solvent mixture. Matrix artefacts were removed by two-step solid-phase extraction process. Three different GC-MS systems [GC-MS (single quadrupole), GC-MS/MS (triple quadrupole) and GC-HRMS (high resolution, magnetic sector)] using the same separation conditions were compared for the analysis of MCS of 3R4F Kentucky reference cigarettes generated under ISO and intense smoking regimes. The high mass resolution (m/∆m ≥ 10,000) and associated selectivity of detection by GC-HRMS provided the highest quality data for the target PAHs in MCS. Owing to the HR data acquisition mode enabling measurement of accurate mass, limits of quantification for PAHs were 5 to 15-fold lower for GC-HRMS than for GC-MS/MS and GC-MS. The presented study illustrates that the optimised sample preparation strategy followed by GC-HRMS analysis provides a fit-for-purpose and robust analytical approach allowing measurement of PAHs at (ultra)low concentrations in MCS. Furthermore, the study illustrates the importance and benefits of robust sample preparation and clean-up to compensate for limited selectivity when low-resolution MS is used.
منابع مشابه
Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry
Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...
متن کاملSimultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry
Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...
متن کاملSimultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry
Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and water for in...
متن کاملDetermination of Polycyclic Aromatic Hydrocarbons in Groundwater Samples by Gas Chromatography-Mass Spectrometry After Pre-Concentration Using Cloud-Point Extraction with Surfactant Derivatization
A cloud-point extraction (CPE) method using the surfactant (30)p-tert-octylphenol polyoxyethylene (OPEO30) was proposed as the preceding step for the determination of polycyclic aromatic hydrocarbons (PAHs) by gas chromatography-mass spectrometry (GC-MS). Given the need for surfactant derivatization before the chromatographic analysis, the reaction conditions of coacervate derivatization were s...
متن کاملDevelopment of a GC-MS Method for Determination of various Polycyclic Aromatic Hydrocarbons in Iranian Traditional and Semi-industrial Taftoon Bread
This research reports a validated multi-residue method based on gas chromatography coupled mass spectrometry technique for analysis of 24 Polycyclic Aromatic Hydrocarbons (PAHs) in traditional and semi-industrial Taftoon bread using QuEChERS sample preparation. Matrix effect studies were performed by comparing the slopes of solvent based standard calibration curves and spiked calibration curves...
متن کامل