AutoGate: Fast and Automatic Doppler Gate Localization in B-Mode Echocardiogram

نویسندگان

  • Jin Hyeong Park
  • Shaohua Kevin Zhou
  • Costas Simopoulos
  • Dorin Comaniciu
چکیده

In this paper, we propose an algorithm for fast and automatic Doppler gate localization in spectral Doppler echocardiography using the B-mode image information. The algorithm has two components: 1) cardiac standard view classification and 2) gate location inference. For cardiac view classification, we incorporate the probabilistic boosting network (PBN) principle to local-structure-dependent object classification, which speeds up the processing time as it breaks down the computational dependency on the number of classes. The gate location is computed using a data-driven shape inference approach. Clinical evaluation was performed by implementing the algorithm on an ultrasound system. Experiment results show that the performance of the proposed algorithm is comparable to the Doppler gate placement by an expert user. To the best of our knowledge, this is the first algorithm that provides a real time solution to the automated Doppler gate placement in the clinical environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler-Derived Myocardial Performance Index in Healthy Children in Shiraz

Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...

متن کامل

طراحی و پیاده‌سازی سامانۀ بی‌درنگ آشکارسازی و شناسایی پلاک خودرو در تصاویر ویدئویی

An automatic Number Plate Recognition (ANPR) is a popular topic in the field of image processing and is considered from different aspects, since early 90s. There are many challenges in this field, including; fast moving vehicles, different viewing angles and different distances from camera, complex and unpredictable backgrounds, poor quality images, existence of multiple plates in the scene, va...

متن کامل

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

A Fast, Robust, Automatic Blink Detector

Introduction “Blink” is defined as closing and opening of the eyes in a small duration of time. In this study, we aimed to introduce a fast, robust, vision-based approach for blink detection. Materials and Methods This approach consists of two steps. In the first step, the subject’s face is localized every second and with the first blink, the system detects the eye’s location and creates an ope...

متن کامل

Comparison between M-Mode and Doppler echocardiography in diagnosis

Introduction: Patent ductus arteriosus (PDA) is the persistence of a normal fetal structure between left pulmonary artery and descending aorta. Persistence of this fetal structure beyond 10 days of life is considered abnormal. In this study we compared M-Mode and Doppler echocardiography in diagnosis of PDA in children at Aliasghar Hospital in Zahedan and Children hospital in Bandar Abbas for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention

دوره 11 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2008