Based on the idea of fault detection and isolation (FDI) for the distributed parameters system, a practical approach of sub-sea pipelines leak detection and location is discussed. The discrete fluid transient equation is linearized and coupled with the extended Kalman filter (EKF) to estimate system state where the only observed data were inlet and outlet flow rate and pressure. The leak estimated location agreed very well with the real location. Because EKF has a time variant track and suit for the stochastic process with Gaussian noise, the parameter sensitivity of DPS fluid transient model was reduced.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

INVERSE FREQUENCY RESPONSE ANALYSIS FOR PIPELINES LEAK DETECTION USING THE PARTICLE SWARM OPTIMIZATION

Inverse Transient Analysis (ITA) is a powerful approach for leak detection of pipelines. When the pipe transient flow is analyzed in frequency domain the ITA is called Inverse Frequency Response Analysis (IFRA). To implement an IFRA for leak detection, a transient state is initiated in the pipe by fast closure of the downstream end valve. Then, the pressure time history at the valve location is...

متن کامل

Statistical Review of Major Standpoints in Hydraulic Transient-Based Leak Detection

Today, pipe systems are the most common facilities to convey various fluids from one place to another. In such facilities faults like leaks lead to advert consequences such as economic losses and social health threats. The fact that early detection of leaks can play a prominent role in reducing the amount of these undesired impacts has absorbed noticeable attention from researchers to this fiel...

متن کامل

Calibration curves for on-line leakage detection using radiotracer injection method

One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl) detectors which were located before and after the considered position, measure emitted gamma from radioactive trac...

متن کامل

Transient Measurement Site Design in pipe networks using the Decision Table Method (DTM)

The accuracy of leak detection and calibration of pipe networks by means of the inverse transient analysis (ITA) is highly affected by the number and location of the measurement sites. This study introduces a conceptual decision-making model, the Decision Table Method (DTM), for the measurement site design of pipe networks with the aim of inverse transient analysis. Through the Decision Table M...

متن کامل

Qualitative Risk Assessment of Gas Pipelines by Using of Indexing System Method in GIS environment

Nowadays the urbanization is developing rapidly, and it leads to growing demand for gas; which resulted in denser pipeline network, by the following increase in the pipeline network congestion, accidents  will become inevitable. So Pipelines are a remarkable source of hazard for their adjacent society. Usually Indexing system method is used for pipe line risk assessment. This method assesses ri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004