Technical challenge of transfemoral aortic valve implantation in a patient with severe aortic regurgitation.

نویسندگان

  • Ulrike Krumsdorf
  • Markus Haass
  • Marcus Pirot
  • Emmanuel Chorianopoulos
  • Hugo A Katus
  • Raffi Bekeredjian
چکیده

Transfemoral aortic valve implantation (TAVI) has become an important interventional technique for patients with severe aortic stenosis (AS) and very high surgical risks. Several studies have demonstrated the feasibility and clinical success of TAVI procedures.1,2 Indications of transfemoral implantations of aortic valves are clearly defined, and TAVI should only be performed in patients with symptomatic severe aortic stenosis, high surgical risks (EuroScore 20%, or other severe concomitant disease that would prohibit surgery), aortic annulus diameter and peripheral vessel diameters within the required dimensions for Edwards Sapien or Medtronic CoreValve devices and sheaths. However, several off-label applications have been described in recent years that could broaden the range of TAVI interventions, such as valve-in-valve implantations in degenerated aortic bioprostheses.3 One of the contraindications for TAVI is severe aortic regurgitation (AR). In severe AR, several technical aspects prohibit TAVI. Aortic annulus shows larger diameters in AR compared with AS. In addition, aortic valve calcification is less pronounced. These two factors make transfemoral aortic valve placement very difficult, with high risks of valve dislocation. In this case report, we present a patient with severe symptomatic aortic regurgitation who underwent transfemoral CoreValve implantation. The patient was an 87-year-old woman with severe AR who suffered from dyspnea on mild exertion (New York Heart Association III). The patient had concomitant coronary artery disease, moderate pulmonary disease, peripheral arteriopathy, and renal failure. Her calculated logistic EuroScore was 46%, and her Society of Thoracic Surgeons score was 22%. Thus, aortic valve replacement was refused both by the patient and the referring physician. Cardiac computed tomography (256-slice) revealed an annulus diameter of 25 mm and mild valve calcification. The annulus diameter was thus still in the range of a 29-mm CoreValve prosthesis (upper range, 27 mm). After careful consideration and the patient had been informed about risks, alternatives, and the off-label application, a 29-mm CoreValve prosthesis was implanted under local anesthesia from the right femoral artery, without valvuloplasty. As expected, CoreValve implantation was challenging. During the first attempt, the partially unfolded CoreValve prosthesis dislocated into the ascending aorta (Figure 1; online-only Data Supplement video 1). The prosthesis was successfully retrieved and reloaded. In the second attempt, the implantation was aimed at a deeper position within the left ventricular outflow tract, and rapid pacing was applied during CoreValve deployment, leading to a successful implantation. After implantation, angiography showed only a trace of paravalvular regurgitation (Figure 2; online-only Data Supplement video 2). The patient recovered quickly and was discharged home after a few days. A control after 6 weeks showed stable position of the CoreValve prosthesis, again with just a trace of paravalvular regurgitation (Figure 2). More importantly, the patient had significantly improved Figure 1. CoreValve prosthesis after dislocation into the ascending aorta.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transapical transcatheter aortic valve implantation followed by transfemoral transcatheter edge-to-edge repair of the tricuspid valve using the MitraClip system – a new treatment concept for an inoperable patient with significant aortic stenosis and severe tricuspid valve regurgitation

Corresponding author: Marek Kowalski MD, PhD, Cardiology Department, Schuechtermann-Klinik, Ulmenallee 5-11, 49214 Bad Rothenfelde, Germany, phone: +49 542464130023, e-mail: [email protected] Received: 3.05.2016, accepted: 11.06.2016. Transapical transcatheter aortic valve implantation followed by transfemoral transcatheter edge-to-edge repair of the tricuspid valve using the M...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

Transfemoral aortic valve implantation in severe aortic stenosis patients with prior mitral valve prosthesis

INTRODUCTION Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. AIM We want to share our experience with transcatheter aor...

متن کامل

A Rare Case of Severe Aortic Regurgitation with Silent Ascending Aortic Dissection

Classically, ascending aortic dissection (AD) presents as sudden, severe chest pain that is tearing type and radiates to the back. Herein, we present a rare case of severe aortic regurgitation with silent ascending AD, which had no chest pain symptoms. The aortic valve apparatus probably masked this AD; therefore, it was not detected by echocardiography and during the surgery.

متن کامل

Transfemoral Implantation of a Fully Repositionable and Retrievable Transcatheter Valve for Noncalcified Pure Aortic Regurgitation.

OBJECTIVES This study sought to evaluate the use of the Direct Flow Medical (DFM) transcatheter heart valve (Direct Flow Medical, Santa Rosa, California) for the treatment of noncalcific pure aortic regurgitation (AR). BACKGROUND The treatment of noncalcific AR has remained a relative contraindication with transcatheter heart valves due to challenges in anchoring devices in the absence of cal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2011