Precipitation with polyethylene glycol and density-gradient ultracentrifugation compared for determining high-density lipoprotein subclasses HDL2 and HDL3.
نویسندگان
چکیده
The purpose of this study was to compare quantification of cholesterol in high-density lipoprotein subfractions HDL2 and HDL3 by precipitation with polyethylene glycol (PEG) with that by density-gradient ultracentrifugation. Fresh serum samples from 32 fasting, obese children were analyzed with precipitation reagent "Quantolip" (Immuno AG), and then fractionated with a Beckman TL 100 ultracentrifuge with a swinging-bucket rotor. After centrifugation we carefully removed the supernate with a syringe and measured the cholesterol from each fraction enzymatically with CHOD-PAP reagent (Boehringer Mannheim). The low-density lipoprotein (LDL-), HDL2-, and HDL3-cholesterol values measured by ultracentrifugation did not differ significantly from those obtained by precipitation; the correlation coefficients (r) between the two methods were 0.96 for LDL, 0.75 for HDL2, and 0.96 for HDL3. The relatively simple PEG precipitation method used in this study measures total HDL and its major subclasses HDL2 and HDL3 with accuracy and precision comparable with those of the well-established ultracentrifugation method.
منابع مشابه
Evaluation of the dual-precipitation method for determination of cholesterol in high-density lipoprotein subfractions HDL2 and HDL3 in serum.
We compared the dual-precipitation method for measurement of cholesterol in high-density lipoprotein subfractions HDL2 and HDL3 (Gidez et al., J Lipid Res 1982;23:1206-33) with density-gradient ultracentrifugation in a swinging-bucket rotor (Demacker et al., Clin Chem 1983;29:656-63). The concentration of dextran sulfate 15,000 (DS) needed for optimal accuracy of the HDL2-chol and HDL3-chol val...
متن کاملCholesterol distribution between high-density-lipoprotein subfractions HDL2 and HDL3 determined in serum by discontinuous gradient gel electrophoresis.
We used discontinuous gradients of polyacrylamide gel to determine the high-density-lipoprotein (HDL) subfractions HDL2 and HDL3 of serum lipoproteins. Serum (40 microL) prestained with Sudan Black was electrophoresed in cylindrical tubes over successive layers of 3.5%, 6%, 13%, and 17.5% acrylamide gels in a Tris.glycine buffer (3-4 h, 300 V). Very-low- (VLDL) and low-density lipoprotein (LDL)...
متن کاملA dual-precipitation method evaluated for measurement of cholesterol in high-density lipoprotein subfractions HDL2 and HDL3 in human plasma.
The dual-precipitation method for measurement of cholesterol in high-density lipoprotein subfractions HDL2 and HDL3 (Warnick et al., Clin Chem 1982;28:1574) was compared with quantification of cholesterol in HDL2 and HDL3 by zonal ultracentrifugation (Patsch et al., J Lipid Res 1974;15:356-66). For 39 plasma specimens differing widely in their HDL subfraction cholesterol concentration, the coef...
متن کاملSeparation and quantitation of subclasses of human plasma high density lipoproteins by a simple precipitation procedure.
Studies in recent years have suggested that measurement of high density lipoprotein (HDL) subclasses may provide significant information beyond that provided by measurement of total HDL. However, conventional methodology for separation of HDL subclasses involves various types of ultracentrifugation that are time-consuming, costly, and not suitable for many clinical or epidemiological studies. W...
متن کاملUse of a dual-precipitation procedure for measuring high-density lipoprotein 3 (HDL3) in normolipidemic serum.
We compared results by a dual-precipitation method (J Lipid Res 1982;23:1206-23) for measuring high-density lipoprotein 3 (HDL3) cholesterol with those by ultracentrifugation at d 1.125, using 56 fresh and 105 frozen-stored serum samples. For both methods, HDL2-cholesterol was calculated as the difference between total HDL-cholesterol and HDL3-cholesterol. In general, for pooled serum samples, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 37 2 شماره
صفحات -
تاریخ انتشار 1991