Muscle shear elastic modulus measured using supersonic shear imaging is highly related to muscle activity level.

نویسندگان

  • Antoine Nordez
  • François Hug
چکیده

This pilot study was designed to determine whether the shear elastic modulus measured using supersonic shear imaging can be used to accurately estimate muscle activity level. Using direct visual feedback of torque, six healthy subjects were asked to perform two incremental isometric elbow flexions, consisting of linear torque ramps of 30 s from 0 to 40% of maximal voluntary contraction. Both electromyographic (EMG) activity and shear elastic modulus were continuously measured in the biceps brachii during the two ramps. There was significant linear regression (P<0.001) between shear elastic modulus and EMG activity level for both ramps of all six subjects (R2=0.94+/-0.05, ranging from 0.82 to 0.98). Good repeatability was found for shear elastic modulus estimated at both 3% (trial 1: 21.7+/-6.7 kPa; trial 2: 23.2+/-7.2 kPa, intraclass correlation coefficient=0.89, standard error in measurement=2.3 kPa, coefficient of variation=12.7%) and 7% (trial 1: 42.6+/-14.1 kPa; trial 2: 44.8+/-15.8 kPa, intraclass correlation coefficient=0.94, standard error in measurement=3.7 kPa, coefficient of variation=7.1%) of maximal EMG activity. The shear elastic modulus estimated at both 3 and 7% of maximal EMG activity was not significantly different (P>0.05) between the two trials. These results confirm our hypothesis that the use of supersonic shear imaging greatly improves the correlation between muscle shear elastic modulus and EMG activity level. Due to the nonlinearity of muscle mechanical properties, the muscle elasticity should be linked to the muscle stress. Therefore, the present study represents a first step in attempting to show that supersonic shear imaging can be used to indirectly estimate muscle stress.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Elbow Flexors Activity Levels during Incremental Isometric Contractions Using Supersonic Shear Imaging

Our previous study has shown that supersonic shear imaging (SSI) can be accurately used to estimate muscle activity level. The present study was designed to assess the muscle activity level of the main elbow flexors using this technique during linear torque ramps of 30 s from 0 to 40% of the previously determined maximal voluntary contraction (MVC). The echographic probe was randomly placed on ...

متن کامل

Estimation of Individual Muscle Force Using Elastography

BACKGROUND Estimation of an individual muscle force still remains one of the main challenges in biomechanics. In this way, the present study aimed: (1) to determine whether an elastography technique called Supersonic Shear Imaging (SSI) could be used to estimate muscle force, (2) to compare this estimation to that one provided by surface electromyography (EMG), and (3) to determine the effect o...

متن کامل

Quantitative Estimation of Muscle Shear Elastic Modulus of the Upper Trapezius with Supersonic Shear Imaging during Arm Positioning

Pain and tenderness of the upper trapezius are the major complaints among people with chronic neck and shoulder disorders. Hyper-activation and increased muscle tension of the upper trapezius during arm elevation will cause imbalance of the scapular muscle force and contribute to neck and shoulder disorders. Assessing the elasticity of the upper trapezius in different arm positions is therefore...

متن کامل

Quantifying the passive stretching response of human tibialis anterior muscle using shear wave elastography.

BACKGROUND Quantifying passive stretching responses of individual muscles helps the diagnosis of muscle disorders and aids the evaluation of surgical/rehabilitation treatments. Utilizing an animal model, we demonstrated that shear elastic modulus measured by supersonic shear wave elastography increases linearly with passive muscle force. This study aimed to use this state-of-the-art technology ...

متن کامل

Shear Elastic Modulus on Patellar Tendon Captured from Supersonic Shear Imaging: Correlation with Tangent Traction Modulus Computed from Material Testing System and Test–Retest Reliability

Characterization of the elastic properties of a tendon could enhance the diagnosis and treatment of tendon injuries. The purpose of this study was to examine the correlation between the shear elastic modulus on the patellar tendon captured from a Supersonic Shear Imaging (SSI) and the tangent traction modulus computed from a Material testing system (MTS) on 8 fresh patellar pig tendons (Experim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 108 5  شماره 

صفحات  -

تاریخ انتشار 2010