Contact allergy to epoxy hardeners.

نویسندگان

  • Kristiina Aalto-Korte
  • Katri Suuronen
  • Outi Kuuliala
  • Maj-Len Henriks-Eckerman
  • Riitta Jolanki
چکیده

BACKGROUND Diglycidylether of bisphenol A resin is the most important sensitizer in epoxy systems, but a minority of patients develop concomitant or solitary contact allergy to epoxy hardeners. At the Finnish Institute of Occupational Health, several in-house test substances of epoxy hardeners have been tested in a special epoxy compound patch test series. OBJECTIVES To analyse the frequency and clinical relevance of allergic reactions to different epoxy hardeners. METHODS Test files (January 1991 to March 2013) were screened for contact allergy to different epoxy hardeners, and the clinical records of patients with allergic reactions were analysed for occupation, concomitant allergic reactions, and exposure. RESULTS The most commonly positive epoxy hardeners were m-xylylenediamine (n = 24), 2,4,6-tris-(dimethylaminomethyl)phenol (tris-DMP; n = 14), isophorone-diamine (n = 12), and diethylenetriamine (n = 9). Trimethylhexamethylenediamine (n = 7), tetraethylenepentamine (n = 4), and triethylenetetramine (n = 2) elicited some reactions, although most patients were found to have no specific exposure. Allergic reactions to hexamethylenetetramine, dimethylaminopropylamine and ethylenediamine dihydrochloride were not related to epoxy products. CONCLUSIONS Tris-DMP is an important sensitizer in epoxy hardeners, and should be included in the patch test series of epoxy chemicals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Occupational contact dermatitis caused by 1,3-benzenedimethanamine, N-(2-phenylethyl) derivatives in hardeners for epoxy paints and coatings.

BACKGROUND Amines in epoxy hardeners are significant causes of occupational allergic contact dermatitis among workers who use epoxy resin systems. OBJECTIVES To describe a novel group of contact allergens: N-(2-phenylethyl) derivatives of the reactive amine 1,3-benzenedimethanamine (1,3-BDMA). METHODS We describe the clinical examinations and exposure of 6 patients with occupational contact...

متن کامل

Sensitization to reactive diluents and hardeners in epoxy resin systems. IVDK data 2002-2011. Part I: reaction frequencies.

BACKGROUND Epoxy resin systems (ERSs), consisting of resins, reactive diluents, and hardeners, are indispensable in many branches of industry. In order to develop less sensitizing ERS formulations, knowledge of the sensitizing properties of single components is mandatory. OBJECTIVES To analyse the frequency of sensitization in the patients concerned, as one integral part of a research project...

متن کامل

Contact allergy to epoxy resins--a 10-year study.

Epoxy resins, widely used as adhesives or coatings in construction, boat and aeroplane building, plastic and other industries and trades (1–3), are a frequent cause of occupational allergic contact dermatitis (1–6). Epoxy resin based on diglycidylether of bisphenol A is the main allergen responsible but sensitization can also develop to other components, including the hardeners and reactive dil...

متن کامل

Sensitization to reactive diluents and hardeners in epoxy resin systems. IVDK data 2002-2011. Part II: concomitant reactions.

BACKGROUND Beside the basic resins, reactive diluents and hardeners are important sensitizers in epoxy resin systems (ERSs). Because of chemical similarities, immunological cross-reactivity may occur. OBJECTIVES To analyse concomitant reactivity among reactive diluents and hardeners in the patients concerned, as one integral part of a research project on the sensitizing capacity of ERSs (FP-0...

متن کامل

Occupational allergic contact dermatitis caused by epoxy chemicals: occupations, sensitizing products, and diagnosis.

BACKGROUND Epoxy products are among the most common causes of occupational allergic contact dermatitis. Diglycidyl ether of bisphenol A resin (DGEBA-R) is the most important sensitizer in epoxy systems. OBJECTIVES To describe patients with occupational allergic contact dermatitis caused by epoxy products. METHODS Patients with allergic reactions to epoxy chemicals were chosen from test file...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Contact dermatitis

دوره 71 3  شماره 

صفحات  -

تاریخ انتشار 2014