Contribution of breast density to the volume of the augmented breast: A preliminary study.

نویسندگان

  • Sean M Hill
  • Franziska Huettner
  • John Murray
  • Eric Elwood
  • Rebecca Barrick
  • Glyn Jones
چکیده

BACKGROUND Prediction of soft tissue contribution to the shape, volume and texture of the augmented breast proves to be an ever-challenging, uncontrollable variable. Similarly, the understanding of the contribution of breast density in breast augmentation has been elusive and, generally, not well studied. OBJECTIVE With the aid of three-dimensional photographic analysis, the present preliminary study examined the contribution of differing breast densities to the overall volume of the augmented breast. METHODS All patients undergoing primary augmentation over a six-month period were included in the study. To standardize technique and implant type, all patients received saline-filled moderate-profile implants, which were placed partially underneath the pectoralis muscle through a lower pole approach. Photographic analysis of the breast volume was completed preoperatively and, subsequently, at a minimum of six months postoperatively. Preoperatively, each breast was also assigned to one of four classes of increasing mammographic density, as judged by the mammographic radiologist (fatty, moderately dense, heterogeneously dense and extremely dense). Postoperative breast volumes were, subsequently, correlated to mammographic densities. RESULTS Thirty-eight augmented breasts in 21 patients were examined. The average volume gain based on the implant size used was 92.7%. Heterogeneously dense breasts comprised 68% of the total breasts and showed an average volume gain of 100.67%, extremely dense breasts comprised 26% of the total breasts and showed an average volume gain of 97.3%, and moderately dense breasts comprised 5% of the total breasts with an average gain of 100.04%. There was no significant difference between the augmented breast volumes and the respective expected volumes (combined preaugmented breast volumes and implant volumes; P=0.3483). Additionally, no statistical difference was found between the density classes and the expected augmented volumes. CONCLUSION No statistical difference was found between expected and actual augmented breast volumes among or between four different breast density classes. Thus, one would expect that the soft tissue compression or the response of the impression of the implant on the parenchyma, would not be statistically different among classes. Additionally, compressive atrophy, as seen with atrophy of the breasts over time, would be expected to be multifactorial and not uniquely independent to breast density. However, longitudinal analysis is needed to study the durability of breast shape relative to breast density.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Factors Affecting the Mammographic Density of Breast Tissue in Patients Referred to the Breast Cancer Research Center, Iran

Introduction: Of the factors leading to false negative results in mammography is breast tissue density, and by increasing the density of breast tissue in mammography, the mammography sensitivity decreases. On the other hand, increasing the breast tissue density leads to increased risk of breast cancer. Various factors such as inheritance, genetics, hormonal and reproductive factors, and nutriti...

متن کامل

Detection of breast cancer using non-invasive X-ray diffraction technique of hair: A preliminary study

Background: An early diagnosis of breast cancer relates directly to an accurate treatment plan and strategy. Early detection of breast cancer before its development would be a significant reduction of morbidity and mortality rates. The aim of this preliminary study is to investigate the sensitivity of Wide Angle X-ray diffraction (WAXRD) method on women hair samples of healthy and breast cancer...

متن کامل

Investigating the Factors Affecting the Mammographic Density of Breast Tissue in Patients Referred to the Breast Cancer Research Center, Iran

Introduction: Of the factors leading to false negative results in mammography is breast tissue density, and by increasing the density of breast tissue in mammography, the mammography sensitivity decreases. On the other hand, increasing the breast tissue density leads to increased risk of breast cancer. Various factors such as inheritance, genetics, hormonal and reproductive factors, and nutriti...

متن کامل

A study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy

Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...

متن کامل

Effects of multiparity and duration of breast-feeding on maternal bone mineral density in post-menopausal Kurdish women: A retrospective study

Introduction:There is considerable amount of controversy about the long term effects of multiparity and duration of breast-feeding on maternal bone mineral density after menopause. This study was conducted to determine whether multiple pregnancy and prolonged duration of breast-feeding are independent predictors of low bone mass in post-menopausal Kurdish women. M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Canadian journal of plastic surgery = Journal canadien de chirurgie plastique

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2011