A self-correcting indirect calorimeter system for the measurement of energy balance in small animals.

نویسندگان

  • D R Jensen
  • E C Gayles
  • S Ammon
  • R Phillips
  • R H Eckel
چکیده

Indirect calorimetry involves measurement of CO(2) produced and O(2) consumed by an organism. These measurements are then used to calculate energy output, metabolic rate (MR), and respiratory quotient (RQ), a relative assessment of carbohydrate and lipid oxidation. By far the most difficult aspect of indirect calorimetry is measurement of O(2). Moreover, the abundance of O(2) (20.95%) relative to CO(2) (0.03%) in ambient conditions dictates that measurement errors of O(2) have greater implications on calculations of MR and RQ. Because compressed air is not feasible for use with animals in long-term experiments, changes in ambient conditions are nearly unavoidable. A self-correcting indirect calorimetry system was designed and constructed utilizing differential O(2) and CO(2) analyzers and a blank cage to monitor ambient conditions periodically. The system was validated by changing ambient O(2) and CO(2) concentrations by infusing N(2) into the system during a test butane burn. MR and RQ were largely unaffected by these changes in ambient conditions, and inclusion of a blank cage in the system accounted for slight calibration offsets. MR and RQ were measured in mice (n = 95) with and without correction for any small changes in ambient conditions measured in the blank cage. Coefficients of variation for MR and RQ were significantly decreased by taking into account ambient conditions measured in the blank cage (P < 0.001), which resulted in a 2.3% increase in precision for measurement of MR. This system will be used to more accurately assess long-term measurements of energy balance in the many murine models of leanness and obesity to gain better insights into pathophysiology and treatment of human obesity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Data Quality Control and Improvement of Indirect Human Calorimeter by System Dynamics Approach J. Futami &H. Kashiwazaki Data Quality Control and Improvement of Indirect Human Calorimeter by System Dynamics Approach

Using a system dynamics approach, a simulation model for data quality control and improvement of human calorimeter using the indirect calorimetry (IHC: indirect human calorimeter) was constructed. Accurate measurements of human energy expenditure are necessary in estimating appropriate energy requirement. IHC can measure continuously energy expenditure over 24 hours. O2 and CO2 analyzers and fl...

متن کامل

Synchronous direct gradient layer and indirect room calorimetry.

A dual direct/indirect room-sized calorimeter is used at the Beltsville Human Nutrition Research Center to measure heat emission and energy expenditure in humans. Because the response times of a gradient layer direct calorimeter and an indirect calorimeter are not equivalent, the respective rate of heat emission and energy expenditure cannot be directly compared. A system of equations has been ...

متن کامل

Optimal Operation of a DWC by Self-Optimizing Control: Active Vapor Split Approach

Dividing Wall Column(DWC) offers the large potential for operating and capital cost saving in compared with conventional distillation sequence. In the studied DWC in this study, the aid of Vmin diagrams, it is shown that without a suitable value for vapor split fraction bellow the dividing wall in different operating conditions, the energy requirement increases from optimal value and it wil...

متن کامل

Intra-individual variability and measurement noise in estimates of energy expenditure by whole body indirect calorimetry.

1. Four men were each studied continuously over 12 d in a whole-body calorimeter. Dietary intake and daily activities were kept constant throughout the study. 2. Day-to-day coefficients of variation in energy expenditure within subjects were found to be 1.97% over 24 h, 5.93% during basal metabolic rate measurement, 2.40% overnight and 3.22% in exercise. 3. The contribution of measurement syste...

متن کامل

سنتز و مشخصه یابی نرم کننده های پر انرژی سازگار با HTPB

Hydroxyl terminated polybutadiene (HTPB) is the most important and versatile binder in composite solid propellant, But the immiscibility of this polymer with traditional energetic plasticizers is a disadvantage limits its application as a binder for compounding of high energy propellant. In this research, two types of energetic plasticizer, 2-ethylhexyl nitrate (2EHN) and 2-ethyl-2-buthyl-1, 3 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 90 3  شماره 

صفحات  -

تاریخ انتشار 2001