Incidence of hardware-related pain and its effect on functional outcomes after open reduction and internal fixation of ankle fractures.

نویسندگان

  • O L Brown
  • D R Dirschl
  • W T Obremskey
چکیده

OBJECTIVES To document the incidence of late pain and hardware removal after open reduction and internal fixation (ORIF) of ankle fractures. To test the hypothesis that late pain overlying the distal tibial and fibular hardware is associated with poorer functional outcomes. DESIGN Retrospective review. SETTING Level II trauma center. PATIENTS One hundred twenty-six skeletally mature patients undergoing ORIF of unstable malleolar fractures who were followed up for at least six months from injury were included. MAIN OUTCOME MEASUREMENTS Analog pain score, Short Form-36 Health Survey (SF-36), and Short Form Musculoskeletal Functional Assessment (SMFA). RESULTS Thirty-nine (31 percent) of the 126 patients had lateral pain overlying their fracture hardware. Twenty-nine patients (23 percent) had had their hardware removed or desired to have it removed. Of the twenty-two patients with hardware-related pain who had undergone hardware removal, only eleven had improvement in their lateral ankle pain; the mean analog pain score decreased from 6 +/- 3.16 (mean +/- standard deviation) before hardware removal to 3 +/- 2.9 after hardware removal (p = 0.008). In general, SF-36 and SMFA scores at final follow-up were significantly lower for patients who had pain overlying their lateral hardware than for those who had no pain. For the group of patients who had lateral ankle pain, no significant difference was noted in SMFA or SF-36 scores for patients who had and who had not had their lateral hardware removed (p > 0.5). CONCLUSION The incidence of late pain overlying the distal tibial and fibular plate or screws is not insignificant. Although pain is generally decreased after hardware removal, nearly half of patients continue to have pain even after hardware removal. Functional outcome scores are poorer for patients with pain overlying lateral ankle hardware than in those with no pain at this location; this poorer outcome seems to be independent of whether the hardware was removed. Although the results of this study do not support or condemn the routine removal of fracture hardware after healing of unstable ankle fractures, they give orthopaedic surgeons some information that may assist them in counseling patients as to the expected functional outcome after ORIF of ankle fractures and the likelihood of relief of pain after removal of fracture hardware from the distal tibia and fibula.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hardware Removal Due to Infection after Open Reduction and Internal Fixation: Trends and Predictors

Background:  Little is known about trends and predictors of hardware related infection following open reduction and internal fixation (ORIF) of extremity fractures, one of the major causes of failure following ORIF. The present study was designed and conducted to determine trends and predictors of infection-related hardware removal following ORIF of extremities using a nationally representative...

متن کامل

Long-term Results, Functional Outcomes and Complications after Open Reduction and Internal Fixation of Neglected and Displaced Greater Tuberosity of Humerus Fractures

  Background: Humerus fractures include 5% to 8% of total fractures. Non-union and delayed union of GT (GT) fractures is uncommon; however they present a challenge to the orthopedic surgeons. Significant controversy surrounds optimal treatment of neglected fractures. The purpose of this article was to perform a comparative study to evaluate the outcomes of open reduction and internal fixatio...

متن کامل

Is Hardware Removal Recommended after Ankle Fracture Repair?

The indications and clinical necessity for routine hardware removal after treating ankle or distal tibia fracture with open reduction and internal fixation are disputed even when hardware-related pain is insignificant. Thus, we determined the clinical effects of routine hardware removal irrespective of the degree of hardware-related pain, especially in the perspective of patients' daily activit...

متن کامل

The Best Option in Treatment of Modified Mason Type III Radial Head Fractures: Open Reduction and Internal Fixation Versus Radial Head Excision

Background: Radial head fractures commonly occur during elbow traumas. Among those, treatment of Mason type IIIfractures is still under controversy. Common treatment methods for these fractures include open reduction and internalfixation (ORIF) as well as radial head excision. In this study, we compared long-term outcomes of both methods intreatment of patients with Mason type III fractures of ...

متن کامل

The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

 Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic trauma

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2001