Images in cardiovascular medicine. Implantable defibrillator generator migration.

نویسندگان

  • A H Dougherty
  • D Wolbrette
چکیده

A 77-year-old man observed abdominal swelling 7 months after epicardial implantation of an automatic implantable defibrillator. He applied an elastic belt to minimize motion of the generator within the pocket and within 2 months noted urinary frequency and rectal fullness. Attempts to locate the generator by palpation and interrogation were unsuccessful. A flat plate of the abdomen (Figure) demonstrated migration of the generator to the superior aspect of the bladder. Surgical exploration revealed a 5x5-cm abdominal wall defect with herniation of small bowel into the generator pocket. The generator had migrated through the hernia defect and into the pelvis. The bowel was reduced back into the peritoneum, and the generator was delivered into its intended pocket with repair of the abdominal wall defect. Normal function of the defibrillator system was confirmed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Implantation of the subcutaneous implantable cardioverter-defibrillator with retroperitoneal generator placement in a child with hypoplastic left heart syndrome

Justin G. Reeves, MD, John S. Kim, MD, Max B. Mitchell, MD, Anthony C. McCanta, MD, FHRS From the Department of Cardiovascular Surgery, School of Medicine, Children’s Hospital Colorado, Aurora, Colorado, University of Colorado Denver, Denver, Colorado, Department of Pediatrics, School of Medicine, Children’s Hospital Colorado, Aurora, Colorado, Department of Cardiovascular Surgery, School of Me...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

The effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)

Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 90 3  شماره 

صفحات  -

تاریخ انتشار 1994