Use of the ISO 9308-1 procedure for the detection of E. coil in water utilizing two incubation temperatures and two confirmation procedures and comparison with defined substrate technology.

نویسندگان

  • C R Fricker
  • S Bullock
  • K Murrin
  • S I Niemela
چکیده

Disinfected and non-disinfected samples have been used to determine the accuracy of the ISO procedure (ISO 9308-1) for detection of E. coli in drinking water. Samples were analysed using the ISO procedure at both 36 and 44 degrees C and using the defined substrate technology method Colilert-18/Quanti-Tray (Colilert-18). Utilizing the confirmation procedure described in ISO 9308-1, large numbers of false positive E. coli results were obtained using the ISO primary isolation procedure at 36 degrees C. However, when glucuronidase production was used as the confirmation procedure, the 'confirmed' count of E. coli was lowest with ISO 9308-1 performed at 36 degrees C. When TTC medium was incubated at 36 degrees C confirmation using production of indole at 44 degrees C resulted in 29% more 'E. coli' being recovered than when confirmation was performed using production of glucuronidase. When 44 degrees C was used as the primary isolation temperature the difference between the number of 'confirmed' E. coli identified using the two confirmation procedures was less than 1% and was not significant. Identification of isolates which 'confirmed' when using production of indole at 44 degrees C as the test method but which failed to produce beta-D-glucuronidase, showed that the majority of these isolates were Klebsiella oxytoca.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

IDEXX Summary 2 P Topic : Use of ISO 9308 - 1 Procedure for the Detection of E . Coli in Water Utilizing Two Incubation

C. R. Fricker (corresponding author) CRF Consulting, Child’s Acre, Church Lane, Three Mile Cross, Reading RG7 1HD, UK Tel.:0774

متن کامل

A comparison of the International Standards Organisation reference method for the detection of coliforms and Escherichia coli in water with a defined substrate procedure.

AIMS This study investigated the use of the International Standards Organisation (ISO) procedure for the comparison of microbiological methods. Using this procedure the ISO reference procedure for the detection of coliforms and Escherichia coli in water was compared with a defined substrate method (ColilertTM). METHODS AND RESULTS A total of 20 laboratories from 13 European countries compared...

متن کامل

Comparison of Colilert-18 with miniaturised most probable number method for monitoring of Escherichia coli in bathing water.

The purpose of this equivalence study was to compare an alternative method, Colilert-18 Quanti-Tray (ISO 9308-2) with the European bathing water directive (2006/7/EC) reference method, the miniaturised most probable number (MMPN) method (ISO 9308-3), for the analysis of Escherichia coli. Six laboratories analysed a total of 263 bathing water samples in Finland. The comparison was carried out ac...

متن کامل

Dependency Coefficient in Computerized GALS Examination Utilizing Motion Analysis Techniques

Objectives: The GALS (Gait, Arms, Legs and Spine) examination is a compact version of standard procedures used by rheumatologists to determine musculoskeletal disorders in patients. Computerization of such a clinical procedure is necessary to ensure an objective evaluation. This article presents the first steps in such an approach by outlining a procedure to use motion analysis techniques as a ...

متن کامل

Design and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study

In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of water and health

دوره 6 3  شماره 

صفحات  -

تاریخ انتشار 2008