Reducing noise in extended depth of field microscope images by optical manipulation of the point spread function

نویسندگان

  • Ramzi N. Zahreddine
  • Robert H. Cormack
  • Carol J. Cogswell
چکیده

This work describes improved methods and algorithms for implementing extended depth of field (EDF) microscopy through point spread function (PSF) engineering. It utilizes adaptive optics to create a test bed on which to evaluate new phase shapes for EDF. Being able to quickly and cheaply design novel PSFs is essential to overcome limitations of EDF that have prevented the technology from reaching mainstream use. Further improvement is made by reducing the noise normally seen in EDF images. Computational optics principles are used to first encode the noise with an identifiable pattern and a specially-tailored non-linear algorithm then removes the noise. This approach improves a microscope's imaging capabilities in photon-starved applications such as live-cell fluorescence and object tracking.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noise removal in extended depth of field microscope images through nonlinear signal processing.

Extended depth of field (EDF) microscopy, achieved through computational optics, allows for real-time 3D imaging of live cell dynamics. EDF is achieved through a combination of point spread function engineering and digital image processing. A linear Wiener filter has been conventionally used to deconvolve the image, but it suffers from high frequency noise amplification and processing artifacts...

متن کامل

Optical depth sectioning in the aberration-corrected scanning transmission and scanning confocal electron microscope

The use of spherical aberration correctors in the scanning transmission electron microscope (STEM) has the effect of reducing the depth of field of the microscope, making three-dimensional imaging of a specimen possible by optical sectioning. Depth resolution can be improved further by placing aberration correctors and lenses pre and post specimen to achieve an imaging mode known as scanning co...

متن کامل

Extended depth-of-field imaging and ranging in a snapshot

Traditional approaches to imaging require that an increase in depth of field is associated with a reduction in numerical aperture, and hence with a reduction in resolution and optical throughput. In their seminal work, Dowski and Cathey reported how the asymmetric point-spread function generated by a cubic-phase aberration encodes the detected image such that digital recovery can yield images w...

متن کامل

Speckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images

Introduction One of the most important pre-processing steps in optical coherence tomography (OCT) is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on ...

متن کامل

Real-time extended depth of field microscopy.

We describe an optical microscope system whose focal setting can be changed quickly without moving the objective lens or specimen. Using this system, diffraction limited images can be acquired from a wide range of focal settings without introducing optical aberrations that degrade image quality. We combine this system with a real time Nipkow disc based confocal microscope so as to permit the ac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012