A multi-sensor upper tropospheric ozone product (MUTOP) based on TES Ozone and GOES water vapor: derivation
نویسندگان
چکیده
The Tropospheric Emission Spectrometer (TES), a hyperspectral infrared instrument on the Aura satellite, retrieves a vertical profile of tropospheric ozone. However, polar-orbiting instruments like TES provide limited nadirview coverage. This work illustrates the value of these observations when taken in context with geostationary imagery describing synoptic-scale weather patterns. The goal of this study is to create map-view products of upper troposphere (UT) ozone through the integration of TES ozone measurements with two synoptic dynamic tracers of stratospheric influence: specific humidity derived from the GOES Imager water vapor absorption channel, and potential vorticity (PV) from an operational forecast model. As a mixing zone between tropospheric and stratospheric reservoirs, the upper troposphere (UT) exhibits a complex chemical makeup. Determination of ozone mixing ratios in this layer is especially difficult without direct in situ measurement. However, it is well understood that UT ozone is correlated with dynamical tracers like low specific humidity and high potential vorticity. Blending the advantages of two remotely sensed quantities (GOES water vapor and TES ozone) is at the core of the Multi-sensor Upper Tropospheric Ozone Product (MUTOP). Our results suggest that 72 % of TES-observed UT ozone variability can be explained by its correlation with dry air and high PV. MUTOP reproduces TES retrievals across the GOES-West domain with a root mean square error (RMSE) of 18 ppbv (part per billion by volume). There are several advantages to this multi-sensor derived product approach: (1) it is calculated from two operational fields (GOES specific humidity and GFS PV), so maps of layer-average ozone can be created and used in near real-time; (2) the product provides the spatial resolution and coverage of a geostationary Correspondence to: S. R. Felker ([email protected]) image as it depicts the variable distribution of ozone in the UT; and (3) the 6 h temporal resolution of the derived product imagery allows for the visualization of rapid movement of this dynamically-driven ozone, as illustrated in the animation Supplement. This paper presents the scientific basis and methodology behind the creation of this unique ozone product, as well as a statistical comparison of the derived product to an evaluation dataset of coincident TES observations.
منابع مشابه
A multi-sensor upper tropospheric ozone product (MUTOP) based on TES ozone and GOES water vapor: validation with ozonesondes
Accurate representation of ozone in the extratropical upper troposphere (UT) remains a challenge. However, the implementation of hyper-spectral remote sensing using satellite instruments such as the Tropospheric Emission Spectrometer (TES) provides an avenue for mapping ozone in this region, from 500 to 300 hPa. As a polar orbiting satellite TES observations are limited, but in this paper they ...
متن کاملStudy of tropospheric ozone concentration trend of Kermanshah by meteorological parameter and ozone precursor and OMI images
Abstract: Clean air is a necessity for human well-being and health. Air pollution is a major threat to humans and other organisms and is considered as one of the environmental challenges. Today, with the increase in air pollution, the need to know more about the causes of its occurrence has been raised. The various consequences of air pollution have made air quality monitoring and control inev...
متن کاملValidation of Tropospheric Emission Spectrometer (TES) measurements of the total, stratospheric, and tropospheric column abundance of ozone
[1] The Tropospheric Emission Spectrometer (TES) is an infrared, high-resolution Fourier transform spectrometer which was launched onboard NASA’s Aura satellite in 2004 and is providing global, vertically resolved measurements of ozone in the troposphere. TES version 2 (V002) data profiles have been validated in the troposphere and lower stratosphere by way of comparison to ozonesondes and airc...
متن کاملCapturing time and vertical variability of tropospheric ozone: A study using TES nadir retrievals
[1] In this paper, the vertical resolution for Tropospheric Emission Spectrometer (TES) nadir ozone retrievals is established and is used to assess the ability of TES to capture time variations of ozone in the troposphere. This characterization is based on retrievals of ozone using simulated radiances generated from ozonesonde profiles taken over Bermuda from 14 April to 25 May 1993. To that en...
متن کاملObserved vertical distribution of tropospheric ozone during the Asian summertime monsoon
[1] We characterize the horizontal and vertical distribution of tropospheric ozone measured by the Tropospheric Emission Spectrometer (TES) over North Africa, the Middle East, and Asia. Studies have shown that the summertime circulation associated with the Asian monsoon significantly influences the spatial distribution of ozone and its precursors. However, there have been limited observations o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011