Characterization of the fatigue behavior of the medial collateral ligament utilizing traditional and novel mechanical variables for the assessment of damage accumulation.
نویسندگان
چکیده
Ligaments are regularly subjected to repetitive loading in vivo. Typically, mechanical studies focus on repetitive loading protocols of short duration, while those characterizing damage accumulation over a longer duration (i.e., fatigue studies) are lacking. The aims of this study were as follows: (a) to demonstrate that damage does accumulate in ligament tissue subjected to repetitive loading and (b) to evaluate existing and new methods for characterizing fatigue damage accumulation. It was hypothesized that ligaments would accumulate damage with repetitive loading as evidenced by failure at stresses well below ultimate tensile strength, creep curve discontinuities, and by reductions in stiffness during loading. Eight normal medial collateral ligaments from female New Zealand white rabbits were cycled in tension, between 0 MPa and 28 MPa, to failure or until 259,200 cycles, whichever came first. Medial collateral ligaments that did not fail were subsequently loaded to failure. Displacement rates (dl(max)/dt) as well as primary, secondary, and tertiary creeps were monitored as indices of damage accumulation and impending mechanical failure. Additionally, the relative utilities of tangent, secant, and chord stiffness parameters were critically evaluated. Finally, new uses for the second derivative of force-displacement data were explored. Three out of eight ligaments failed during testing, demonstrating that ligaments can fail in fatigue under moderate tensile stress in vitro. The evaluation of displacement rates (dl(max)/dt), as well as primary through tertiary creep patterns, were not well suited to predicting failure in normal ligaments until rupture was all but imminent. Tangent stiffness, which was calculated from a mathematically defined start of the "linear region," was surprisingly constant throughout testing. Secant stiffness dropped in a predictable fashion, providing a global indicator of tissue stiffness, but did not provide any insight into fiber mechanics. Chord stiffness, on the other hand, appeared to be sensitive to fiber recruitment patterns. The second derivative of force-displacement data proved to be a useful means of (a) objectively defining the start of the linear region and (b) inferring changes in fiber recruitment patterns within ligament tissue. Tangent, secant, and chord stiffnesses highlight different attributes of ligament responses to loading; hence these parameters cannot be used interchangeably. Additionally, the second derivative of the force-displacement curve was introduced as a useful descriptive and analytical tool.
منابع مشابه
Medial Collateral Ligament Injury; A New Classification Based on MRI and Clinical Findings. A Guide for Patient Selection and Early Surgical Intervention
Medial collateral ligament (MCL)injury, is one of the most common ligament injuries of the knee,mostly results from a valgus force.Restoration of function and going back to the pre-injury level of function is the aim of treatment in ligament injuries of the knee. There are multiple soft tissue structures in medial side that play an important role in connection with each other to retain medial s...
متن کاملAnatomical Repair of Stener-like Lesion of Medial Collateral Ligament: A case Series and Technical Note
Medial collateral ligament tears usually will be treated through non-surgical methods, but, in some cases such as thosewith tears at the distal insertion where the reduction could be blocked by the pes anserine tendons (Stener-like lesion), surgerywill be performed. Here, we present a surgical technique in such cases. In this retrospective case series, we describesix patients diagnosed with Ste...
متن کاملSIMULTANEOUS RECONSTRUCTION OF MEDIAL COLLATERAL LIGAMENT AND POSTERIOR CRUCIATE LIGAMENT VIA SINGLE MEDIAL FEMORAL TUNNEL : A MODIFIED TECHNIQUE AND CASE SERIES
This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran
متن کاملEffect of Low-Power Helium-Neon Laser Irradiation on Collagen Fibril Thickness of Incisized Medial Collateral Ligament of Knee in Rat
Purpose: The aim of the present study is to investigate the effect of low-power Helium-Neon laser (LPL) on collagen fibril thickness of incisized medial collateral ligament of knee joint (MCL) in rat. Materials and Methods: MCL of right hind limb of 35 male adult sprague Dawley rat under general anesthesia were transversly incisized. Rats were randomly divitded into normal, control, first lase...
متن کاملFatigue Life Assessment of Composite Airplane Wing Subjected to Variable Mechanical and Thermal Loads
The purpose of this paper is to estimate the fatigue life of an airplane wing with laminated composite skin, subjected to variable mechanical and thermal loads. To achieve this aim,at first, the three-dimensional model of airplane wing was drawn in CATIA software. Then, by transferring the model to the ABAQUS software, the finite element model of the wing wascreated. H...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanical engineering
دوره 132 1 شماره
صفحات -
تاریخ انتشار 2010