Aptamer-based SERRS sensor for thrombin detection.
نویسندگان
چکیده
We describe an aptamer-based surface enhanced resonance Raman scattering (SERRS) sensor with high sensitivity, specificity, and stability for the detection of a coagulation protein, human alpha-thrombin. The sensor achieves high sensitivity and a limit of detection of 100 pM by monitoring the SERRS signal change upon the single-step of thrombin binding to immobilized thrombin binding aptamer. The selectivity of the sensor is demonstrated by the specific discrimination of thrombin from other protein analytes. The specific recognition and binding of thrombin by the thrombin binding aptamer is essential to the mechanism of the aptamer-based sensor, as shown through measurements using negative control oligonucleotides. In addition, the sensor can detect 1 nM thrombin in the presence of complex biofluids, such as 10% fetal calf serum, demonstrating that the immobilized, 5'-capped, 3'-capped aptamer is sufficiently robust for clinical diagnostic applications. Furthermore, the proposed sensor may be implemented for multiplexed detection using different aptamer-Raman probe complexes.
منابع مشابه
Aptamer Based Microsphere Biosensor for Thrombin Detection
We have developed an optical microsphere resonator biosensor using aptamer as receptor for the measurement of the important biomolecule thrombin. The sphere surface is modified with anti-thrombin aptamer, which has excellent binding affinity and selectivity for thrombin. Binding of the thrombin at the sphere surface is monitored by the spectral position of the microsphere’s whispering gallery m...
متن کاملAnalytical performances of aptamer-based sensing for thrombin detection.
Aptamer-based assays represent a modern and attractive approach in bioanalytical chemistry. The DNA thrombin aptamer has been extensively investigated, and the coupling of this aptamer to different transduction principles has demonstrated the wide applicability of aptamers as bioreceptors in bioanalytical assays. The goal of this work was to critically evaluate all the parameters that can influ...
متن کاملA Guided Mode Resonance Aptasensor for Thrombin Detection
Recent developments in aptamers have led to their widespread use in analytical and diagnostic applications, particularly for biosensing. Previous studies have combined aptamers as ligands with various sensors for numerous applications. However, merging the aptamer developments with guided mode resonance (GMR) devices has not been attempted. This study reports an aptasensor based home built GMR ...
متن کاملAptamer-Based Single-Step Assay by the Fluorescence Enhancement on Electroless Plated Nano Au Substrate
A new single-step aptamer-based surface-enhanced fluorescent optical sensor is built, by combining an aptamer-target interaction for target recognition and a fluorophore interaction for signal enhancement. The developed aptasensor is simple, sensitive, specific and stable for the detection of thrombin. A new nanometallic Au structure in the range of 100 nm was constructed through effective elec...
متن کاملA sensitive strategy for label-free and time-resolved fluorescence assay of thrombin using Tb-complex and unmodified gold nanoparticles.
Gold nanoparticles (GNPs) can effectively differentiate the unfolded and folded aptamer, and quench the fluorescence of terbium ternary complexes (Tb-complexes), thus the authors herein report a sensitive strategy for protein detection, using label-free aptamer, Tb-complexes and GNPs. In the presence of thrombin, the aptamer is inclined to form G-quartet, and the folded aptamer cannot adsorb on...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nano letters
دوره 8 12 شماره
صفحات -
تاریخ انتشار 2008