Ocular rigidity, outflow facility, ocular pulse amplitude, and pulsatile ocular blood flow in open-angle glaucoma: a manometric study.

نویسندگان

  • Anna I Dastiridou
  • Evangelia E Tsironi
  • Miltiadis K Tsilimbaris
  • Harilaos Ginis
  • Nikos Karyotakis
  • Pierros Cholevas
  • Sofia Androudi
  • Ioannis G Pallikaris
چکیده

PURPOSE To compare ocular rigidity (OR) and outflow facility (C) coefficients in medically treated open-angle glaucoma (OAG) patients and controls, and to investigate differences in ocular pulse amplitude (OPA) and pulsatile ocular blood flow (POBF) between the two groups. METHODS Twenty-one OAG patients and 21 controls undergoing cataract surgery were enrolled. Patients with early or moderate primary or pseudoexfoliative OAG participated in the glaucoma group. A computer-controlled system, consisting of a pressure transducer and a microstepping device was employed intraoperatively. After cannulation of the anterior chamber, IOP was increased by infusing the eye with microvolumes of saline solution. IOP was recorded after each infusion step. At an IOP of 40 mm Hg, an IOP decay curve was recorded for 4 minutes. OR coefficients, C, OPA, and POBF were estimated from IOP and volume recordings. RESULTS There were no differences in age or axial length in the two groups. The OR coefficient was 0.0220 ± 0.0053 μl(-1) in the OAG and 0.0222 ± 0.0039 μl(-1) in the control group (P = 0.868). C was 0.092 ± 0.082 μL/min/mm Hg in the glaucoma group compared with 0.149 ± 0.085 μL/min/mm Hg in the control group at an IOP of 35 mm Hg (P < 0.001) and 0.178 ± 0.133 μL/min/mm Hg vs. 0.292 ± 0.166 μL/min/mm Hg, respectively, at an IOP of 25 mm Hg (P < 0.001). There were no differences in OPA or POBF between the two groups in baseline and increased levels of IOP (P > 0.05). CONCLUSIONS Manometric data reveal lower C in OAG patients and increased C with increasing IOP. There were no differences in the OR coefficient, OPA, and POBF between medically treated OAG patients and controls, failing to provide evidence of altered scleral distensibility and choroidal blood flow in OAG.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Postural studies in pulsatile ocular blood flow: II. Chronic open angle glaucoma.

The pulsatile ocular blood flow (POBF) has been recorded in 15 patients with chronic open angle glaucoma. Measurements were performed during regular treatment with timolol 0.25% eyedrops, two weeks after withdrawal of this treatment, and then a further two weeks after its reinstitution. Readings were taken with subjects in both the erect and supine positions by means of a pneumotonometric probe...

متن کامل

Estimation of ocular rigidity based on measurement of pulse amplitude using pneumotonometry and fundus pulse using laser interferometry in glaucoma.

PURPOSE There is evidence from theoretical models and animal studies that the biomechanical properties of the optic nerve head and the sclera play a role in the pathophysiology of glaucoma. There are, however, only a few data available that demonstrate such biomechanical alterations in vivo. In this study, the hypothesis was that patients with primary open-angle glaucoma (POAG) have an abnormal...

متن کامل

Rho Kinase Inhibitors as a Novel Treatment for Glaucoma and Ocular Hypertension

In an elegant example of bench-to-bedside research, a hypothesis that cells in the outflow pathway actively regulate conventional outflow resistance was proposed in the 1990s and systematically pursued, exposing novel cellular and molecular mechanisms of intraocular pressure (IOP) regulation. The critical discovery that pharmacologic manipulation of the cytoskeleton of outflow pathway cells dec...

متن کامل

مقایسه تاثیر تیمولول و بتاکسولول بر کاهش فشار داخل چشمی و عوارض موضعی و سیستمیک آنها

Background and purpose: This is a study to compare the efficacy and side effects of betaxolol and timolol in lowering the IOP of primary open angle glaucoma or ocular hypertension. Materials and Methods: This Double-blind randomized cross-over clinical trial was conducted on 29 eyes of 20 patients with primary open angle glaucoma or ocular hypertension. Each patient received timolol 0.5% a...

متن کامل

SCIENTIFIC CORRESPONDENCE Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension

Background/aim: Intraocular pressure (IOP) is not a fixed constant value but rather has pulsatile components associated with cardiac action. The SmartLens dynamic observing tonometer (odc, Ophthalmic Development Company AG, Zurich, Switzerland) can measure and record simultaneously IOP and ocular pulse amplitude (OPA). It was the aim of this study to evaluate OPA in patients with primary open a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 54 7  شماره 

صفحات  -

تاریخ انتشار 2013