Central corneal thickness measurements with optical coherence tomography and ultrasound pachymetry in healthy subjects and in patients after photorefractive keratectomy.
نویسندگان
چکیده
PURPOSE To compare central corneal thickness measurements made using two different methods, optical coherence tomography (OCT) and ultrasound pachymetry, applied both in normal eyes and in eyes on which photorefractive keratectomy (PRK) had been performed. A second objective was to assess the intrasession variability of OCT measurements. METHODS In this prospective study, central corneal thickness was measured in 20 normal subjects (normal group) and in 20 PRK patients using the StratusOCT instrument model 3000 (Carl Zeiss Meditec), and also with an ultrasound pachymeter. Five OCT measurements were performed using the Fast Macular Thickness protocol. Corneal thickness data were obtained with the Scan Profile analysis protocol. The OCT measurement results were compared with the mean value of three ultrasound pachymetry measurements for the same eye. RESULTS The pachymetry-OCT correlation coefficients were 0.96 and 0.97 in the normal and PRK groups, respectively (p=0.14). Neither linear regression nor Bland-Altmann analysis revealed any significant systematic measurement error. Intrasession standard deviations in the normal and PRK groups were 4.9 microm and 3.8 microm, respectively. CONCLUSIONS Noncontact central corneal thickness measurements made using the StratusOCT instrument are accurate and reproducible, both in normal subjects and in post-PRK patients. The instrument system does not need any modifications to correctly detect and measure the center of the cornea.
منابع مشابه
Central Corneal Thickness in Highly Myopic Eyes: Inter-device Agreement of Ultrasonic Pachymetry, Pentacam and Orbscan II Before and After Photorefractive Keratectomy
PURPOSE To determine inter-device agreement for central corneal thickness (CCT) measurement among ultrasound pachymetry, rotating Scheimpflug imaging (Pentacam, Oculus, Wetzlar, Germany), and scanning slit corneal topography (Orbscan II, Bausch & Lomb, Rochester, NY, USA) in highly myopic eyes before and after photorefractive keratectomy (PRK). METHODS This prospective comparative study inclu...
متن کاملIntraoperative Pachymetry Using Spectral-Domain Optical Coherence Tomography during Accelerated Corneal Collagen Crosslinking
PURPOSE To evaluate the role of spectral-domain optical coherence tomography (SDOCT) to measure corneal thickness during accelerated corneal crosslinking (CXL). METHODS Intraoperative pachymetry was performed using SDOCT and ultrasound pachymetry (USP) in 6 eyes of 6 patients with keratoconus. Pachymetry readings were obtained at baseline, after epithelium removal and after 30 minutes of ribo...
متن کاملRetinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography
Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...
متن کاملRole of Optical Coherence Tomography on Corneal Surface Laser Ablation
This paper focuses on reviewing the roles of optical coherence tomography (OCT) on corneal surface laser ablation procedures. OCT is an optical imaging modality that uses low-coherence interferometry to provide noninvasive cross-sectional imaging of tissue microstructure in vivo. There are two types of OCTs, each with transverse and axial spatial resolutions of a few micrometers: the time-domai...
متن کاملComparison of central corneal thickness: ultrasound pachymetry versus slit-lamp optical coherence tomography, specular microscopy, and Orbscan
BACKGROUND Central corneal thickness (CCT) can be measured by using contact and non-contact methods. Ultrasound pachymetry (US pachymetry) is a contact method for measuring CCT and is perhaps the most commonly used method. However, non-contact methods like scanning slit topography (Orbscan II), slit-lamp optical coherence tomography (SL-OCT), and specular microscopy are also used. Not many stud...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of ophthalmology
دوره 19 2 شماره
صفحات -
تاریخ انتشار 2009