An improved method for automatic segmentation of the left ventricle in myocardial perfusion SPECT.
نویسندگان
چکیده
UNLABELLED This study describes and validates a new method for automatic segmentation of left ventricular mass (LVM) in myocardial perfusion SPECT (MPS) images. This is important for estimating the size of a perfusion defect as percentage of the left ventricle. METHODS A total of 101 patients with known or suspected coronary artery disease underwent both rest and stress MPS and MRI. A new automated algorithm was trained in 20 patients (40 MPS studies) and tested in 81 patients (162 MPS studies). The algorithm, which segmented the left ventricle in the MPS images, is based on Dijkstra's algorithm and finds an optimal mid-mural line through the left ventricular wall. From this line, the endocardium and epicardium are identified on the basis of an individually estimated wall thickness and signal intensity. The algorithm was validated by comparing LVM in both stress and rest MPS, with LVM of the manually segmented left ventricle from MRI as the reference standard. For comparison, LVM was quantified using the software quantitative perfusion SPECT (QPS). RESULTS The mean difference+/-SD in LVM between MPS and MRI was lower for the new method (6%+/-15% LVM) than for QPS (18%+/-19% LVM) for both mean difference (P<0.001) and SD (P=0.015). Linear regression analysis of LVM, comparing MPS and MRI, yielded R2=0.83 using the new method and R2=0.80 using QPS. Interstudy variability, measured as the coefficient of variance between rest MPS and stress MPS, was 6% for both the new method and QPS. Both the new algorithm and QPS systematically overestimated LVM in hearts with thin myocardium and underestimated LVM in hearts with thick myocardium. CONCLUSION The new segmentation algorithm quantifies LVM with a significantly lower bias and variability than does the commercially available QPS software, when compared to manually segmented LVM by MRI. This makes the new algorithm an attractive method to use for estimating the size of the perfusion defect when expressing it as percentage of the left ventricle. This study shows that inaccurate estimation of wall thickness is the main source of error in automatic segmentation.
منابع مشابه
The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method
Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملDetection of Cardiac Artery Disease by Using the DCAD (b) Module
Introduction: In patients with cardiac artery disease, a myocardial perfusion scan, which is a non-invasive method, is utilized. This study is conducted to develop an advantageous software applicable to quantitative myocardial SPECT perfusion. Material and Methods: Each cross-section of the left ventricle was segmented by applying a fuzzy clustering method. After obtaining the myocardial skelet...
متن کاملDipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings
Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...
متن کاملAutomatic Segmentation of the Left Ventricle in 3D SPECT Data by Registration with a Dynamic Anatomic Model
We present a fully automatic 3D segmentation method for the left ventricle (LV) in human myocardial perfusion SPECT data. This model-based approach consists of 3 phases: 1. finding the LV in the dataset, 2. extracting its approximate shape and 3. segmenting its exact contour. Finding of the LV is done by flexible pattern matching, whereas segmentation is achieved by registering an anatomical mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 50 2 شماره
صفحات -
تاریخ انتشار 2009