Sensitivity, reproducibility, and accuracy in short tandem repeat genotyping using capillary array electrophoresis.

نویسندگان

  • E S Mansfield
  • M Vainer
  • S Enad
  • D L Barker
  • D Harris
  • E Rappaport
  • P Fortina
چکیده

The Human Genome Initiative has increased significantly the rate at which disease-causing genes are being mapped and sequenced. New cost-effective methods to locate the genes and to characterize disease-causing mutations require robust, reproducible, and accurate protocols for measuring DNA fragment lengths. Capillary array electrophoresis (CAE) offers rapid, high-resolution separations, high throughput, and sensitive detection. To assess the utility of CAE for the accumulation of genetic information, we tested both sizing accuracy and reproducibility using 48-capillary prototype systems. Two multiplex PCR allelic ladder standards and several CA-repeat markers were analyzed in > 100 runs. Reproducibility in typing > 8000 genotypes reveals a standard deviation of less than 0.2 bp on these systems under optimized conditions. However, sequence-dependent migration anomalies were observed at most simple sequence loci even when analyzed under denaturing conditions, resulting in a systematic bias in estimated fragment sizes. We show here that, by normalizing results to known typing controls, one can obtain locus-averaged accuracies of < 0.06 bp and normalized results within 1 bp of actual. We detect as little as a 1:30,000 dilution of a DNA quantitation standard stained with highly sensitive intercalating dyes, indicating an 80-zeptomole sensitivity limit. However, to obtain reproducible electrokinetic injection, approximately 200 attomoles of fluorescein-labeled DNA is required. These sensitivity limits, sizing precision, and accuracy, together with the 1-hr run times for 48-96 samples, indicate that CAE is a viable method for high-throughput genetic analysis of simple sequence repeat polymorphisms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short Tandem Repeat Genotyping Using Capillary Array Electrophoresis

The Human Genome Initiative has increased significantly the rate at which disease-causing genes are being mapped and sequenced. New cost-effective methods to locate the genes and to characterize disease-causing mutations require robust, reproducible, and accurate protocols for measuring DNA fragment lengths. Capillary array electrophoresis (CAE) offers rapid, high-resolution separations, high t...

متن کامل

Brain tumor cell line authentication, an efficient alternative to capillary electrophoresis by using a microfluidics-based system.

BACKGROUND The current method for cell line authentication is genotyping based on short tandem repeat (STR)-PCR involving coamplification of a panel of STR loci by multiplex PCR and downstream fragment length analysis (FLA), usually performed by capillary electrophoresis. FLA by capillary electrophoresis is time-consuming and can be expensive, as the facilities are generally not accessible for ...

متن کامل

Brain tumour cell line authentication, an efficient alternative to capillary electrophoresis by using a microfluidics-based system

Background. The current method for cell line authentication is short tandem repeat PCR (STR-PCR) -based genotyping involving co-amplification of a panel of STR loci by multiplex PCR and the downstream fragment length analysis (FLA), usually performed by capillary electrophoresis. FLA by capillary electrophoresis is time-consuming and can be expensive as the facilities are generally not accessib...

متن کامل

Y-STR genetic screening by high-resolution melting analysis.

Currently, the widely used automated capillary electrophoresis-based short tandem repeat (STR) genotyping method for genetic screening in forensic practice is laborious, time-consuming, expensive, and technically challenging in some cases. Thus, new molecular-based strategies for conclusively identifying forensically relevant biological evidence are required. Here, we used high-resolution melti...

متن کامل

High-Throughput STR Analysis by Time-of-Flight Mass Spectrometry

Rapid, cost-effective methods for high-throughput DNA analysis are needed to process samples currently being gathered for large criminal DNA databases around the world. Within the U.S., several states have sample backlogs of over 50,000 samples with limited funds and manpower to analyze these samples. Currently available slab gel or capillary electrophoresis instruments can handle only a few do...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Genome research

دوره 6 9  شماره 

صفحات  -

تاریخ انتشار 1996