Managing femoral bone loss in revision total hip replacement: fluted tapered modular stems.
نویسندگان
چکیده
If a surgeon is faced with altered lesser trochanter anatomy when revising the femoral component in revision total hip replacement, a peri-prosthetic fracture, or Paprosky type IIIb or type IV femoral bone loss, a modular tapered stem offers the advantages of accurately controlling femoral version and length. The splines of the taper allow rotational control, and improve the fit in femoral canals with diaphyseal bone loss. In general, two centimetres of diaphyseal contact is all that is needed to gain stability with modular tapered stems. By allowing the proximal body trial to rotate on a well-fixed distal segment during trial reduction, appropriate anteversion can be obtained in order to improve intra-operative stability, and decrease the dislocation risk. However, modular stems should not be used for all femoral revisions, as implant fracture and corrosion at modular junctions can still occur.
منابع مشابه
Tapered modular fluted titanium stems for femoral fixation in revision total knee arthroplasty
Consensus regarding femoral stem fixation options in revision total knee arthroplasty remains controversial. Tapered, modular, fluted titanium (TMFT) stems have an excellent track record in total hip arthroplasty for their ability to provide axial and rotational stability in situations of compromised host bone. We present 3 successfully treated cases in which the Food & Drug Administration gran...
متن کاملRevision total hip arthroplasty in patients with extensive proximal femoral bone loss using a fluted tapered modular femoral component.
Revision total hip arthroplasty (THA) is challenging when there is severe loss of bone in the proximal femur. The purpose of this study was to evaluate the clinical and radiographic outcomes of revision THA in patients with severe proximal femoral bone loss treated with a fluted, tapered, modular femoral component. Between January 1998 and December 2004, 92 revision THAs were performed in 92 pa...
متن کاملOsteointegration of an uncemented modular revision stem implanted during revision hip surgery.
BACKGROUND Though mid-term survival rates of over 95% in several series have been published, there is still a paucity of related literature regarding the role of vertical stem instability in the osteointegration of fluted tapered stems. This paper presents a comprehensive and prospective assessment on short-term experiences with uncemented modular femoral stem in the treatment of defective femu...
متن کاملModular tapered titanium stems in revision arthroplasty of the hip: The Risk and Causes of Stem Fracture.
Tapered fluted titanium stems are increasingly used for femoral revision arthroplasty. They are available in modular and non-modular forms. Modularity has advantages when the bone loss is severe, the proximal femur is mis shapen or the surgeon is unfamiliar with the implant, but it introduces the risk of fracture of the stem at the junction between it and the proximal body segment. For that rea...
متن کاملTapered fluted modular titanium stems in the management of Vancouver B2 and B3 peri-prosthetic fractures.
Tapered, fluted, modular, titanium stems are increasingly popular in the operative management of Vancouver B2 and selected B3 peri-prosthetic femoral fractures. We have reviewed the results at our institution looking at stem survival and clinical outcomes and compared this with reported outcomes in the literature. Stem survival at a mean of 54 months was 96% in our series and 97% for combined p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The bone & joint journal
دوره 95-B 11 Suppl A شماره
صفحات -
تاریخ انتشار 2013