OBJECTIVE To determine if an interlocking bolt would limit subsidence of the biological fixation universal hip (BFX(®)) femoral stem under cyclic loading and enhance construct stiffness, yield, and failure properties. STUDY DESIGN Ex vivo biomechanical study. ANIMALS Cadaveric canine femora (10 pairs). METHODS Paired femora implanted with a traditional stem or an interlocking stem (constructs) were cyclically loaded at walk, trot, and gallop loads while implant and bone motions were captured using kinematic markers and high-speed video. Constructs were then loaded to failure to evaluate failure mechanical properties. RESULTS Implant subsidence was greater (P = .037) for the traditional implant (4.19 mm) than the interlocking implant (0.78 mm) only after gallop cyclic loading, and cumulatively after walk, trot, and gallop cyclic loads (5.20 mm vs. 1.28 mm, P = .038). Yield and failure loads were greater (P = .029 and .002, respectively) for the interlocking stem construct (1155 N and 2337 N) than the traditional stem construct (816 N and 1405 N). Version angle change after cyclic loading was greater (P = .020) for the traditional implant (3.89 degrees) than for the interlocking implant (0.16 degrees), whereas stem varus displacement at failure was greater (P = .008) for the interlocking implant (1.5 degrees) than the traditional implant (0.17 degrees). CONCLUSION Addition of a stabilizing bolt enhanced construct stability and limited subsidence of a BFX(®) femoral stem. Use of the interlocking implant may decrease postoperative subsidence. However, in vivo effects of the interlocking bolt on osseointegration, bone remodeling, and stress shielding are unknown.
منابع مشابه
Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملSimultaneous and multisite measure of micromotion, subsidence and gap to evaluate femoral stem stability.
The initial stability of cementless femoral components is crucial for the long-term success of total hip arthroplasty. This has been reported in animal and clinical studies. Until now, the stability was evaluated by the measurement of relative micromotion on a few simultaneous locations around the stem in cadaveric experiments. This paper presents an extended experimental setup to measure simul...
متن کاملIs stem design important in uncemented total hip replacement to decrease subsidence in obese patients?
© Annals of Joint. All rights reserved. Ann Joint 2017;2:50 aoj.amegroups.com There has been a world-wide trend towards cementless total hip replacement (THR) over the last 20 years (1). One of the primary reasons for the introduction of the cementless stem was to improve the outcome in younger, more active patients, particularly males. The New Zealand Joint Registry (NZJR) has shown a revision...
متن کاملEffects of teriparatide on cementless bipolar hemiarthroplasty in patients with osteoporotic femoral neck fractures
BACKGROUND For osteoporotic femoral neck fractures, suitable bone-implant stability is critical for pain relief, early return to daily activities and reduction of complications. Teriparatide (parathyroid hormone [PTH1-34]) can improve bone-implant stability in some basic studies. However it's use in osteoporotic femoral neck fractures treated by cementless hemiarthroplasties for the beneficial ...
متن کامل10-year experience with short stem total hip arthroplasty.
Since 1998, short stem total hip arthroplasty (THA) has been performed at the authors' institution. Currently, 30% of THAs are performed with short stems. This article reports on complications that required revision of a short stem THA. Between September 2005 and February 2012, a total of 1953 Metha short stem THAs were performed; of these, 38 required revision due to mechanical complications. ...
متن کامل