Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention
نویسنده
چکیده
In percutaneous coronary interventions, drug-eluting stents (DESs) have reduced the risk of restenosis and repeat revascularization compared with bare-metal stents. The secondgeneration DESs with thinner stent struts have improved safety and efficacy compared with the first-generation DESs and has been associated with a reduced risk of late stent thrombosis. The persistence of polymer material on firstand second-generation DESs after completion of drug release has been Background—Coronary drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy. Methods and Results—The Scandinavian Organization for Randomized Trials With Clinical Outcome (SORT OUT) VII trial—a large-scale registry-based randomized, multicenter, single-blind, 2-arm, noninferiority trial—compared 2 biodegradable polymer drug-eluting stents: the thin-strut cobalt–chromium sirolimus-eluting Orsiro stent and the stainless steel biolimus-eluting Nobori stent in an all-comer patient population. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 1 year, analyzed by intention to treat (noninferiority margin of 3.0%). Clinically driven event detection based on Danish registries was used. A total of 1261 patients were assigned to receive the sirolimus-eluting stent (1590 lesions) and 1264 patients to the biolimus-eluting stent (1588 lesions). At 1 year, the composite end point target lesion failure occurred in 48 patients (3.8%) in the sirolimus-eluting group and in 58 patients (4.6%) in the biolimus-eluting group (absolute risk difference, −0.78% [upper limit of 1-sided 95% confidence interval, 0.61%]; P<0.0001). Rates of definite stent thrombosis occurred in 5 (0.4%) of the sirolimus-eluting group compared with 15 (1.2%) biolimus-eluting stent–treated patients (rate ratio, 0.33; 95% confidence interval, 0.12–0.92; P=0.034), which largely was attributable to a lower risk of subacute definite stent thrombosis: 0.1% versus 0.6% (rate ratio, 0.12; 95% confidence interval, 0.02–1.00; P=0.05). Conclusions—The thin-strut sirolimus-eluting Orsiro stent was noninferior to the biolimus-eluting Nobori stent in unselected patients for target lesion failure at 1 year. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT01879358. (Circ Cardiovasc Interv. 2016;9:e003610. DOI: 10.1161/CIRCINTERVENTIONS.115.003610.)
منابع مشابه
Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial.
BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-...
متن کاملBiolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): a randomised non-inferiority trial.
BACKGROUND Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer-coated sirolimus-eluting stent in a population-based setting. METHODS This randomised, ...
متن کاملUltrathin Strut Biodegradable Polymer Sirolimus‐Eluting Stent Versus Durable‐Polymer Everolimus‐Eluting Stent for Percutaneous Coronary Revascularization: 2‐Year Results of the BIOSCIENCE Trial
BACKGROUND No data are available on the long-term performance of ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES). We reported 2-year clinical outcomes of the BIOSCIENCE (Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularisation) trial, which compared BP-SES with durable-polyme...
متن کاملBiodegradable polymer drug-eluting stents reduce the risk of stent thrombosis at 4 years in patients undergoing percutaneous coronary intervention: a pooled analysis of individual patient data from the ISAR-TEST 3, ISAR-TEST 4, and LEADERS randomized trials.
AIMS The efficacy of durable polymer drug-eluting stents (DES) is delivered at the expense of delayed healing of the stented vessel. Biodegradable polymer DES aim to avoid this shortcoming and may potentially improve long-term clinical outcomes, with benefit expected to accrue over time. We sought to compare long-term outcomes in patients treated with biodegradable polymer DES vs. durable polym...
متن کاملEffect of biolimus-eluting stents with biodegradable polymer vs bare-metal stents on cardiovascular events among patients with acute myocardial infarction: the COMFORTABLE AMI randomized trial.
CONTEXT The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). OBJECTIVE To compare stents eluting biolimus from a biodegradable polymer with bare-metal stents in primary PCI. DESIGN, SETTING, AND PATIENTS A prospectiv...
متن کامل