Comparison between Rendering 3d-ct and Transparent 3d-ct in Acl Tunnel Positioning
نویسندگان
چکیده
OBJECTIVE To compare the transparent 3D computed tomography (CT) image protocol against conventional 3D-CT image-rendering protocol to assess femoral tunnel position in anatomic anterior cruciate ligament (ACL) reconstructions . METHODS Eight knee CT scans from cadavers were analyzed by image rendering 3D-CT protocol, using Rhinoceros(r) software. The central point of the ACL tunnel was set using the sagittal plane. Same CT scans were analyzed using transparent 3D-CT measurement protocol with OsiriX(r) software. Central point of the ACL tunnel was set using sagittal, coronal and axial planes. The grid system described by Bernard and Hertel was used to compare tunnel positions between protocols, using height and length parameters . RESULTS There was a significant difference between measurements using image rendering 3D-CT and transparent 3D-CT protocol for height (23.8 ± 7.9mm and 33.0 ± 5.0mm, respectively; p=0.017) and no differences for length (18.6 ± 4.2mm and 18.3 ± 4.5mm, respectively; p=0.560) . CONCLUSION Height in transparent CT protocol was different and length was the same as compared to 3D-CT rendering protocol in Bernard and Hertel method for tunnel measurements. Level of Evidence II, Descriptive Laboratory Study.
منابع مشابه
External radiotherapy of intact breast: A comparison between 2D (single CT- slice) and 3D (full CT-slices) plans
Background: Tangential irradiation of intact breast is one of the most common procedures performed in any radiotherapy center. This method is performed by using 2D and 3D treatment planning. The aim of this study was to compare 2D with 3D plans in breast conserving radiotherapy. Homogeneity of isodose, and lung received dose were compared. Materials and Methods: Twenty patients with br...
متن کاملEvaluation of Femoral Tunnel Positioning Using 3-Dimensional Computed Tomography and Radiographs after Single Bundle Anterior Cruciate Ligament Reconstruction with Modified Transtibial Technique
BACKGROUND The purpose of this study is to report a modified transtibial technique to approach the center of anatomical femoral footprint in anterior cruciate ligament (ACL) reconstruction and to investigate the accurate femoral tunnel position with 3-dimensional computed tomography (3D-CT) and radiography after reconstruction. METHODS From December 2010 to October 2011, we evaluated 98 patie...
متن کاملTomographic Study of Femoral Positioning in Anterior Cruciate Ligament Reconstruction Using the Transtibial Technique
Purpose To analyze the location of the femoral tunnel by three-dimensional computed tomography (3D CT) of the lateral condyle in patients who underwent arthroscopic single-bundle anterior cruciate ligament (ACL) reconstruction, performed using a modified transtibial technique, and to compare the results with data from the literature. Materials and Methods Seventeen patients with ACL lesions u...
متن کاملMeasurements of bone tunnel size in anterior cruciate ligament reconstruction: 2D versus 3D computed tomography model
BACKGROUND Revision anterior cruciate ligament (ACL) reconstruction requires a precise evaluation of previous tunnel locations and diameters. Enlargement of the tunnels, despite not usually affecting primary reconstruction outcomes, plays an important role in revision ACL management. Three dimensional (3D) computed tomography (CT) models are reported to be the most accurate method for identifyi...
متن کاملVisualization of postoperative anterior cruciate ligament reconstruction bone tunnels
BACKGROUND AND PURPOSE Non-anatomic bone tunnel placement is the most common cause of a failed ACL reconstruction. Accurate and reproducible methods to visualize and document bone tunnel placement are therefore important. We evaluated the reliability of standard radiographs, CT scans, and a 3-dimensional (3D) virtual reality (VR) approach in visualizing and measuring ACL reconstruction bone tun...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 25 شماره
صفحات -
تاریخ انتشار 2017