Intravascular ultrasound predictors of outcome after peripheral balloon angioplasty.

نویسندگان

  • E J Gussenhoven
  • A van der Lugt
  • G Pasterkamp
  • F G van den Berg
  • L H Sie
  • M Vischjager
  • S H The
  • W Li
  • H Pieterman
  • H van Urk
چکیده

OBJECTIVE This study investigates the potential role of intravascular ultrasound (IVUS) in the outcome in patients undergoing percutaneous transluminal angioplasty (PTA) of the superficial femoral artery. MATERIALS Angiographic and the qualitative and quantitative IVUS data obtained at the narrowest site derived from 39 patients before and after PTA were analysed. RESULTS Angiographically the diameter of the remaining stenosis seen after PTA was classified as < 50% in 31 patients (success); in eight patients a failure was encountered. Evaluating at 6 months the functional and anatomic results of the PTA in 31 patients, the intervention was a success in 14 patients (Group I) and a failure in 17 patients (Group II). The remaining eight patients defined as angiographic failure following PTA comprised Group III. Neither qualitative nor quantitative IVUS data obtained before PTA could predict outcome. Conversely, after PTA, the extent of dissection was significantly more severe in Groups II and III than in Group I. Similarly, significant differences were found between Groups I and II for mean free lumen area (13.2 vs. 9.7 mm2, respectively) and mean free lumen diameter (4.1 vs. 3.5 mm, respectively). Quantitative data obtained in Group II were similar to those in Group III. CONCLUSION This preliminary study demonstrates that following PTA the extent of dissection, free lumen area and diameter seen with IVUS are predictive factors of patency. Future studies with more patients are mandatory to further highlight the sensitivity of these observations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Observational Study Using Intravascular Ultrasound

Background. Atherosclerotic plaque fracture and dissection of the arterial wall are frequent concomitants of the balloon angioplasty process. The composition and morphology of plaque within the vessel may be critical in determining the extent of plaque fracture and dissection during balloon angioplasty. To examine this potential association in the clinical setting, we studied patients with intr...

متن کامل

Interobserver reproducibility of qualitative and quantitative analysis of intravascular ultrasound images before and after peripheral balloon angioplasty.

In this study, interobserver agreement on intravascular ultrasound data obtained before and after balloon angioplasty (PTA) of the superficial femoral artery was assessed. Two observers analyzed intravascular ultrasound cross-sections from 38 patients. Interobserver agreement was good for soft and hard lesions, dissection and vascular damage (kappa values 0.61, 0.67, 0.69 and 0.66, respectively...

متن کامل

Contribution of localized calcium deposits to dissection after angioplasty. An observational study using intravascular ultrasound.

BACKGROUND Atherosclerotic plaque fracture and dissection of the arterial wall are frequent concomitants of the balloon angioplasty process. The composition and morphology of plaque within the vessel may be critical in determining the extent of plaque fracture and dissection during balloon angioplasty. To examine this potential association in the clinical setting, we studied patients with intra...

متن کامل

Catheter for Percutaneous Transluminal Angioplasty Validation of Imaging, Analysis of Recoil, and Identification of Plaque Fracture

Background. We investigated the hypothesis that an ultrasound transducer positioned within an angioplasty balloon could be used to perform quantitative assessment of arterial dimensions before and after percutaneous transluminal angioplasty (PTA) and to identify certain mechanical alterations consequent to PTA, including vascular wall recoil and the initiation of plaque fractures. Methods and R...

متن کامل

Combination balloon-ultrasound imaging catheter for percutaneous transluminal angioplasty. Validation of imaging, analysis of recoil, and identification of plaque fracture.

BACKGROUND We investigated the hypothesis that an ultrasound transducer positioned within an angioplasty balloon could be used to perform quantitative assessment of arterial dimensions before and after percutaneous transluminal angioplasty (PTA) and to identify certain mechanical alterations consequent to PTA, including vascular wall recoil and the initiation of plaque fractures. METHODS AND ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery

دوره 10 3  شماره 

صفحات  -

تاریخ انتشار 1995