Compton scattering spectroscopy for determining filtration of a clinical computed tomography system
نویسندگان
چکیده
Purpose: Compton spectroscopy is a widely accepted tool for measuring the primary X-ray spectra of a diagnostic computed tomography (CT) system. The aim of this work is to spectroscopically detect CT X-ray photons subjected to 90-degree Compton scattering for accurate modelling of CT beam-shaping filtration, which necessary for computation of radiation exposure and for other research applications in medical physics. Methods: For a tube potential of 120 kVp X-ray spectra have been measured under fan angles of 0° to 20° in steps of 2° and at 21° from the central ray. At each fan angle the value of the X-ray path length determining the relative filter transmission was iteratively varied in order to estimate the thickness of the aluminium filter and the filter geometry was implemented in a Monte Carlo (MC) simulation of the CT scanner. Results: Direct comparison of measured and simulated filtered X-ray spectra indicates that the spectra match very well, with a correlation of 1 for small fan angles (below 4°) and an average correlation of 0.996 for the whole field-of-view (FOV). Conclusion: The agreement between the simulated X-ray spectra and the measured spectra suggest that spectral measurements using Compton spectroscopy across the fan beam of a CT system are suitable for modelling the beam-shaping filtration currently used in commercially available CT systems.
منابع مشابه
An iterative method to estimate x-ray attenuation coefficients in computed tomography
Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (D...
متن کاملDetermining the accuracy of measuring the thickness of steel plates using Compton scattering method
When there is limitation access to one side of the structure in industry, one of the best methods for thickness measurements is the Compton scattering. In this paper, due to the statistical behavior of dispersed beam counting, we discuss the accuracy of the measurement for steel thickness. Using the experimental method and comparing it with MCNP simulation code, the accuracy is obtained less th...
متن کاملCompton scattering as a probe for materials investigation
This article investigates into the feasibility of using gamma radiation Compton backscatter spectra as a means of material characterization, with the view to developing a portable, hand held probe for investigative purposes such as searching for illicit substances hidden in wall or car door cavities.
متن کاملImage Optimization in Single Photon Emission Computed Tomography by Hardware Modifications with Monte Carlo Simulation
Introduction: In Single Photon Emission Computed Tomography (SPECT), the projection data used for image reconstruction are distorted by several factors, including attenuation and scattering of gamma rays, collimator structure, data acquisition method, organ motion, and washout of radiopharmaceuticals. All these make reconstruction of a quantitative SPECT image very difficult. Simulation of a SP...
متن کاملMonte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کامل