A mercury(II) ion-selective electrode based on N,N-dimethylformamide-salicylacylhydrazone as a neutral carrier.
نویسندگان
چکیده
A new PVC membrane mercury(II) ion electrode based on N,N-dimethylformamide-salicylacylhydrazone (DMFAS) as an ionophore is described, which shows excellent potentiometric response characteristics and displays a linear log[Hg(2+)] versus EMF response over a wide concentration range between 6.2 x 10(-7) and 8.0 x 10(-2) M with a Nerstian slope of 29.6 mV per decade and a detection limit of 5.0 x 10(-7) M. The response time for the electrode is less than 30 s and the electrode can be used for more than 2 months with less than a 2 mV observed divergence in a potentials. The proposed electrode exhibits very good selectivity for mercury(II) ions over many cations in a wide pH range (pH 1 - 4). The electrode was also applied to the determination of a mercury(II) ion in vegetables and in Azolla filiculoides.
منابع مشابه
(1E,2E) -bis (2-aminophenyl) N'1,N'2-dihydroxyethane bis (imidothioate) as a neutral carrier in ion-selective electrode for Ni(II) and it computational studies
A PVC membrane Ni(II) ion selective electrode has been constructed using (1E,2E)-bis(2-aminophenyl)N'1,N'2-dihydroxyethanebis as membrane carrier. The electrode exhibited a goodpotentiometric response for Ni(II) over a wide concentration range 1.0×10-4 to 1.0×10-1M with aslope of 29.4±0.5 mV/decade a and a working pH range of 6.5-9.0. It had a fast response time of≤20s. The best performance was...
متن کاملManganese (M-selective PVC membrane electrode based on N-(2- picolinamido ethyl)-Picolinamide as ionophore
In this research, a PVC membrane electrode for Manganese (II) ions based on N-(2-Picolinamidoethyl)Picolinamide as neutral carrier was prepared. The electrode exhibits a Nemstian responseover Mn(II) concentration range of (1.0 x10-5 t01.0 X 10-1M) with a slope of 29.3±0.5 mV perdecade of concentration with a working pH range of 4.0-9.0. It has a fast response time (
متن کاملFe (II) Ion-Selective Membrane Electrode based onTetra-Phenyl Porphyrin in PVC Matrix
Fe2+ ion-selective membrane sensor has been fabricated from polyvinyl chloride (PVC) matrixmembrane containing neutral carrier tetra phenyl porphyrin (TPP) ionophore. The addition ofsodium tetraphenylborate (NaTPB) and the plasticizer DBP has been found to substantiallyimprove the performance of the sensor. The best performance was obtained with the sensor havinga membrane of composition of TPP...
متن کاملChromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier
A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...
متن کاملNovel ZrO2 ion-selective electrode based on 4,7,13,16,21,24-hexa oxa- 1,10- diazabicyc1o[8,8,8]-hexa cosane as neutral carrier in PVC matrix
In this work, a novel Zr02+ PVC-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (HODBHC) as a new ionophore is presented. The sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 M, with a near Nernstian slope of 29.9 ± 0.4 mV per decade in an acidic solution(pH=1). The limit of detection is 8.0 x 1 0 7 M. The electrodes possess adv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 22 4 شماره
صفحات -
تاریخ انتشار 2006