Non-Invasive Prenatal Chromosomal Aneuploidy Testing - Clinical Experience: 100,000 Clinical Samples

نویسندگان

  • Ron M. McCullough
  • Eyad A. Almasri
  • Xiaojun Guan
  • Jennifer A. Geis
  • Susan C. Hicks
  • Amin R. Mazloom
  • Cosmin Deciu
  • Paul Oeth
  • Allan T. Bombard
  • Bill Paxton
  • Nilesh Dharajiya
  • Juan-Sebastian Saldivar
  • Michael Edward Zwick
چکیده

OBJECTIVE As the first laboratory to offer massively parallel sequencing-based noninvasive prenatal testing (NIPT) for fetal aneuploidies, Sequenom Laboratories has been able to collect the largest clinical population experience data to date, including >100,000 clinical samples from all 50 U.S. states and 13 other countries. The objective of this study is to give a robust clinical picture of the current laboratory performance of the MaterniT21 PLUS LDT. STUDY DESIGN The study includes plasma samples collected from patients with high-risk pregnancies in our CLIA-licensed, CAP-accredited laboratory between August 2012 to June 2013. Samples were assessed for trisomies 13, 18, 21 and for the presence of chromosome Y-specific DNA. Sample data and ad hoc outcome information provided by the clinician was compiled and reviewed to determine the characteristics of this patient population, as well as estimate the assay performance in a clinical setting. RESULTS NIPT patients most commonly undergo testing at an average of 15 weeks, 3 days gestation; and average 35.1 years of age. The average turnaround time is 4.54 business days and an overall 1.3% not reportable rate. The positivity rate for Trisomy 21 was 1.51%, followed by 0.45% and 0.21% rate for Trisomies 18 and 13, respectively. NIPT positivity rates are similar to previous large clinical studies of aneuploidy in women of maternal age ≥ 35 undergoing amniocentesis. In this population 3519 patients had multifetal gestations (3.5%) with 2.61% yielding a positive NIPT result. CONCLUSION NIPT has been commercially offered for just over 2 years and the clinical use by patients and clinicians has increased significantly. The risks associated with invasive testing have been substantially reduced by providing another assessment of aneuploidy status in high-risk patients. The accuracy and NIPT assay positivity rate are as predicted by clinical validations and the test demonstrates improvement in the current standard of care.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive prenatal testing for rare chromosomal anomalies

Correspondence: Dr. C.A. Ionescu e-mail: antoniuginec@ yahoo.com After numerous clinical validation studies, non-invasive prenatal testing for fetal aneuploidy detection is now a clinical reality. While non-invasive prenatal testing was accepted due to the high accuracy for fetal trisomy (21, 18 and 13) detection, recent research showed that genome-wide analysis is able to detect other fetal an...

متن کامل

O-45: Quantification of Cell-Free-Fetal-DNAfrom Maternal Plasma for the First Time in Pakistan:Implications for Non-Invasive PrenatalDiagnosis of Genetic Disorders

Background: Current prenatal diagnosis requires invasive testing which carries a 1-4% procedure-related-risk of miscarriage; hence, non-invasive techniques are desired. The recent demonstration of cell-free-fetal-DNA enriched from maternal plasma has opened new possibilities for non-invasive-prenatal-diagnosis of not only genetic-disorders such as β-thalassaemia and haemophilia but also chromos...

متن کامل

Beyond Trisomy 21: Additional Chromosomal Anomalies Detected through Routine Aneuploidy Screening

Prenatal screening is often misconstrued by patients as screening for trisomy 21 alone; however, other chromosomal anomalies are often detected. This study aimed to systematically review the literature and use diagnostic meta-analysis to derive pooled detection and false positive rates for aneuploidies other than trisomy 21 with different prenatal screening tests. Non-invasive prenatal testing ...

متن کامل

Implementation of non‐invasive prenatal testing by semiconductor sequencing in a genetic laboratory

OBJECTIVES To implement non-invasive prenatal testing (NIPT) for fetal aneuploidies with semiconductor sequencing in an academic cytogenomic laboratory and to evaluate the first 15-month experience on clinical samples. METHODS We validated a NIPT protocol for cell-free fetal DNA sequencing from maternal plasma for the detection of trisomy 13, 18 and 21 on a semiconductor sequencing instrument...

متن کامل

Non-invasive prenatal testing using cell-free fetal DNA in maternal circulation.

The identification of cell-free fetal DNA (cffDNA) in maternal circulation has made non-invasive prenatal testing (NIPT) possible. Maternal plasma cell free DNA is a mixture of maternal and fetal DNA, of which, fetal DNA represents a minor population in maternal plasma. Therefore, methods with high sensitivity and precision are required to detect and differentiate fetal DNA from the large backg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014