Evaluation of Ultrasonography to Measure Fetal Size and Heart Rate as Predictors of Fetal Age in Hair Sheep

نویسنده

  • R. W. Godfrey
چکیده

There is little information available on methods to estimate fetal age of hair sheep. The objective of this study was to determine whether crown-rump length (CRL) and/or fetal heart rate (FHR) could be used to predict fetal age in hair sheep using transrectal B-mode and Doppler ultrasonography. St Croix White, Barbados Blackbelly and Dorper X St. Croix White ewes (n = 54) were scanned weekly beginning 28 d after a successful mating. Linear array B-mode ultrasonography (5 MHz) was used to measure CRL and visual FHR, and Doppler ultrasonography was used to measure audible FHR. Due to the size of the fetus CRL was not measurable after 42 d of gestation, and visual FHR was Evaluation of Ultrasonography to Measure Fetal Size and Heart Rate as Predictors of Fetal Age in Hair Sheep

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

گزارش یک مورد نادر رابدومیوما در قلب جنین: گزارش موردی

Background: The primary manifestation of cardiac tumors in embryonic period is a very rare condition. Cardiac rhabdomyomas most frequently arise in the ventricular myocardium, they may also occur in the atria and the epicardial surface. In spite of its benign nature, the critical location of the tumor inside the heart can lead to lethal arrhythmias and chamber obstruction. Multiple rhabdomyomas...

متن کامل

Comparison of Fetal Echocardiography for Fetal Cardiac Structure in Women with Gestational Diabetes Mellitus and Normal Pregnancies

BackgroundIncreased metabolic rate of hyperglycemia in gestational diabetes causes macrosomia, which can also affect the fetal heart. The thickness of the walls of the heart and its function in women with gestational diabetes mellitus (GDM) can change over time before treatment. We aimed to evaluate fetal cardiac structure in terms of ventricular wall thickness and its function in women w...

متن کامل

A PCA/ICA based Fetal ECG Extraction from Mother Abdominal Recordings by Means of a Novel Data-driven Approach to Fetal ECG Quality Assessment

Background: Fetal electrocardiography is a developing field that provides valuable information on the fetal health during pregnancy. By early diagnosis and treatment of fetal heart problems, more survival chance is given to the infant.Objective: Here, we extract fetal ECG from maternal abdominal recordings and detect R-peaks in order to recognize fetal heart rate. On the next step, we find a be...

متن کامل

Estimation of Fetal Weight by Clinical Methods and Ultrasonography and Comparing With Actual Birth Weight

Introduction: Assessment of fetal weight is a vital factor in antenatal care, not only in the management of labor and delivery but also in identifying fetal weight disorders. Objective: This study compares the accuracy of clinical methods and ultrasonography in Estimating Fetal Weight (EFW) with Actual Birth Weight (ABW) in term pregnant women. Materials and Methods: This diagnostic test eval...

متن کامل

Ultrasonographic fetal scapular length measurement for assessment of gestational age

one of the major goals of antenatal care is estimation of gestational age.the most widely used parameters for evaluation of fetal growth are biparietal diameter (BPD),femoral length (FL) and adbominal circumference (AC).to determine the value of prenatal ultrasonographic scapula measurements for fetal growth and gesattional age a prospective ultrasonographic cross-sectional study was conducted ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011