Imaging of the Lamina Cribrosa using Swept-Source Optical Coherence Tomography.

نویسندگان

  • Brenda Nuyen
  • Kaweh Mansouri
  • Robert N Weinreb
چکیده

The lamina cribrosa (LC) is the presumed site of axonal injury in glaucoma. Its deformation has been suggested to contribute to optic neuropathy by impeding axoplasmic flow within the optic nerve fibers, leading to apoptosis of retinal ganglion cells. To visualize the LC in vivo, optical coherence tomography (OCT) has been applied. Spectral domain (SD)-OCT, used in conjunction with recently introduced enhanced depth imaging (EDI)-OCT, has improved visualization of deeper ocular layers, but in many individuals it is still limited by inadequate resolution, poor image contrast and insufficient depth penetrance. The posterior laminar surface especially is not viewed clearly using these methods. New generation high-penetration (HP)-OCTs, also known as swept-source (SS)-OCT, are capable to evaluate the choroid in vivo to a remarkable level of detail. SS-OCTs use a longer wavelength (1,050 nm instead of 840 nm) compared to the conventional techniques. We review current knowledge of the LC, findings from trials that use SD-OCT and EDI-OCT, and our experience with a prototype SS-OCT to visualize the LC in its entirety. Key Points What is known? •     The LC is the presumed site of axonal injury in glaucoma •     Compared to spectral domain-OCT, enhanced depth imaging-OCT improves imaging of the LC •     Even so, currently used SD-OCT techniques are restricted by poor wavelength penetrance of the deeper ocular layers What our findings add? •    SS-OCT may be a superior imaging modality for deep ocular structures •    Prior studies used SS-OCT to evaluate choroidal thickness in both healthy and 'normal tension glaucoma' eyes •    SS-OCT enables good evaluation of three-dimension (3D) lamina cribrosa morphology. How to cite this article: Nuyen B, Mansouri K, Weinreb RN. Imaging of the Lamina Cribrosa using Swept-Source Optical Coherence Tomography. J Current Glau Prac 2012;6(3): 113-119.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional imaging of lamina cribrosa defects in glaucoma using swept-source optical coherence tomography.

PURPOSE To visualize lamina cribrosa defects using three-dimensional (3D) swept-source optical coherence tomography (SS-OCT), and to determine the factors associated with this feature. METHODS All subjects were examined using an SS-OCT prototype system, which uses a tunable laser as a light source, operated at 100,000 Hz A-scan repetition rate in the 1050-nm wavelength. A 3D raster scan proto...

متن کامل

Positional and Curvature Difference of Lamina Cribrosa According to the Baseline Intraocular Pressure in Primary Open-Angle Glaucoma: A Swept-Source Optical Coherence Tomography (SS-OCT) Study

PURPOSE To investigate the variation of lamina cribrosa (LC) structure based on the baseline intraocular pressure (IOP) in eyes with primary open-angle glaucoma (POAG) and healthy individuals using swept-source optical coherence tomography. METHODS A total of 108 eyes with POAG and 61 healthy eyes were recruited. Based on the baseline IOP, the POAG eyes were divided into higher-baseline IOP (...

متن کامل

Imaging limbal and scleral vasculature using Swept Source Optical Coherence Tomography.

We demonstrate an application of high-speed swept source optical coherence tomography for vessel visualization in the anterior segment of the human eye. The human corneo-scleral junction and sclera was imaged in vivo. Imaging was performed using a swept source OCT system operating at the 1050nm wavelength range and 100kHz A-scan rate. High imaging speed enables the generation of 3D depth-resolv...

متن کامل

Full-range polarization-sensitive swept-source optical coherence tomography by simultaneous transversal and spectral modulation.

Polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) is used to measure three-dimensional phase-retardation images of birefringent biological tissue in vivo. PS-SS-OCT with continuous source polarization modulation is used to multiplex the incident states of polarization in the signal frequency of each A-scan. Although it offers the advantage of measurement speed that is...

متن کامل

Lamina cribrosa visibility using optical coherence tomography: comparison of devices and effects of image enhancement techniques.

PURPOSE To compare the visibility of the lamina cribrosa (LC) in optic disc images acquired from 60 glaucoma and 60 control subjects using three optical coherence tomography (OCT) devices, with and without enhanced depth imaging (EDI) and adaptive compensation (AC). METHODS A horizontal B-scan was acquired through the center of the disc using two spectral-domain (Spectralis and Cirrus; with a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of current glaucoma practice

دوره 6 3  شماره 

صفحات  -

تاریخ انتشار 2012