Technical note: comparison between single and multiview simulated DXA configurations for reconstructing the 3D shape and bone mineral density distribution of the proximal femur.
نویسندگان
چکیده
PURPOSE Dual-energy x-ray absorptiometry (DXA) is used in clinical routine to provide a two-dimensional (2D) analysis of the bone mineral density (BMD). 3D reconstruction methods from 2D DXA images could improve the BMD analysis. To find the optimal configuration that should be used in clinical routine, this paper relies on a 3D reconstruction method from DXA images to compare the accuracy that can be obtained from one single-view and from multiview DXA images (two to four projections). METHODS The 3D reconstruction method uses a statistical model and a nonrigid registration technique to recover in 3D the shape and the BMD distribution of the proximal femur. The accuracy was evaluated in vivo by comparing 3D reconstructions obtained from simulated DXA images of 30 patients (using between one and four DXA views) with quantitative computed tomography reconstructions. RESULTS This comparison showed that the use of one single DXA provides accurate 3D reconstructions (mean shape accuracy of 1.0 mm and BMD distribution errors of 7.0%). Among the multiview configurations, the use of two views (0° and 45°) was the best compromise, increasing the accuracy of pose (mean accuracy of 0.7°/1.2°/0.9° against 1.0°/3.5°/3.3° for the single view), reducing slightly the BMD errors (5.7%) while maintaining the same shape accuracy. CONCLUSIONS The use of two views constitutes an interesting configuration when multiview DXA devices are available in clinical routine. However, the use of only one single view remains an accurate solution to recover the shape and the BMD distribution in 3D, with the advantage of a higher potential for clinical translation.
منابع مشابه
3D bone mineral density distribution and shape reconstruction of the proximal femur from a single simulated DXA image: an in vitro study
Area Bone Mineral Density (aBMD) measured by Dual energy X-ray Absorptiometry (DXA) is an established criterion in the evaluation of hip fracture risk. The evaluation from these planar images however is limited to 2D while it has been shown that proper 3D assessment of both the shape and the BMD distribution improves the fracture risk estimation. In this work we present a method to reconstruct ...
متن کاملComparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis
Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...
متن کاملBone Mineral Density in Egyptian Children with Familial Mediterranean Fever
Background: Familial Mediterranean fever (FMF) has episodic or subclinical inflammation that may lead to a decrease in bone mineral density (BMD). The objective of this study was to assess BMD in Egyptian children with FMF on genetic basis.Methods: A cross sectional study included 45 FMF patients and 25 control children of both sexes in the age range between 3-16 years old. The patients were re...
متن کاملA software framework for 3D reconstruction and fracture risk assessment of the proximal femur from dual-energy x-ray absorptiometry
In clinical routine, osteoporosis diagnosis is performed using the areal Bone Mineral Density (aBMD) computed from two-dimensional Dual-energy X-ray Absorptiometry (DXA) images. This measurement of the "projected density" gives a global marker of osteoporosis but is insufficient for an accurate quantification of non-uniform mineral deficiencies. Quantitative Computed Tomography (QCT) is one pos...
متن کاملAssessment of bone mineral density with dual energy X-ray absorptiometry in pre- and post-menopausal women
Background: Osteoporosis is a chronic disease that contributes substantially to decrease physical activity and decline in the quality of life. Osteoporosis can be diagnosed easily with the use of dual-energy X-ray absorptiometry (DXA) equipment. The aim of this study was to investigate the magnitude of bone loss on proximal femur and lumbar spine LS in pre- and post-menopausal women f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 39 8 شماره
صفحات -
تاریخ انتشار 2012