Utility of multiple-echo data image combination sequence for SPIO-enhanced T2*-weighted MR imaging of liver MRI at 3.0 T system

نویسندگان

  • J. Choi
  • M-J. Kim
  • J. Kim
  • J-Y. Choi
  • Y. Chung
چکیده

Introduction At 3.0 T MR system, superparamagnetic iron oxide (SPIO)-enhanced liver magnetic resonance imaging (MRI) may have the theoretical advantage of high SNR and high liver to lesion contrast, because of stronger susceptibility effect compared with that at 1.5 T. On T2*-weighted gradient recalled echo (GRE) sequences essential for SPIO-enhanced liver MRI, positive effects of 3T on lesion-to-liver CNR were offset by the substantially reduced image quality, secondary to motion and susceptibility artifacts. MEDIC (multiple-echo data image combination) sequence can provides a potential solution by using a series of GRE images at different echo times. Purpose We assessed the utility of T2*-weighted MEDIC sequence for SPIO-enhanced liver MRI at 3T system. Materials and Methods Fifty patients with 76 hepatic lesions (48 solid lesions, 26 non-solid lesions) underwent SPIO-enhanced MRI at 3T system using T2*-weighted fast imaging with steady precession (FISP) (TR/TE, 126/9; flip angle, 30°) and MEDIC (TR/TE, 186/9; flip angel, 30°) sequences. Three radiologists independently reviewed images in random order. Sensitivity and accuracy for the detection of focal hepatic lesions were compared by analyzing the area under the receiver operating characteristic curve. Image artifacts (flow artifact, susceptibility artifact, dielectric artifact, motion artifact), lesion conspicuity and overall image quality were evaluated according to a 4 point scale: 1, poor; 2. fair; 3, good; 4, excellent. Signal–to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the lesion were compared. Results Image artifacts were more frequent on FISP (p<0.05). Mean scale of image artifacts were 2.76, 3.13, 3.42 and 2.89 for flow artifact, susceptibility artifact, dielectric artifact and motion artifact on FISP, 3.47, 3.43, 3.47 and 3.39 on MEDIC. There was no significant difference of lesion conspicuity between FISP (3.15) and MEDIC (3.30). Overall image quality was significantly (p<0.05) better on MEDIC (3.37)than on FISP (2.89). The mean SNR and CNR of the lesion were significantly (p<0.05) higher on MEDIC (79±23 and 128±59, respectively) than on FISP (38±11 and 102±44). Lesion detection accuracy and sensitivity were not significantly different between FSIP and MEDIC. Mean accuracies and sensitivities were 0.864 and 0.785 for FISP and 0.847 and 0.785 for MEDIC. Conclusion At 3T system, MEDIC sequence can be a useful alternative sequence to replace FISP sequence for SPIO-enhanced MRI by improving overall image quality and decreasing flow artifact and undesired susceptibility artifacts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Bifunctional Gadolinium-Labeled Superparamagnetic Nanoparticles (Gd-MnMEIO) for In Vivo MR Imaging of the Liver in an Animal Model.

Liver tumors are common and imaging methods, particularly magnetic resonance imaging (MRI), play an important role in their non-invasive diagnosis. Previous studies have shown that detection of liver tumors can be improved by injection of two different MR contrast agents. Here, we developed a new contrast agent, Gd-manganese-doped magnetism-engineered iron oxide (Gd-MnMEIO), with enhancement ef...

متن کامل

Detection of hypervascular hepatocellular carcinoma: comparison of SPIO-enhanced MRI with dynamic helical CT.

PURPOSE The purpose of this study was to compare the diagnostic performance of superparamagnetic iron oxide (SPIO)-enhanced MRI for the detection of hypervascular hepatocellular carcinoma (HCC) with dynamic helical CT. METHODS SPIO-enhanced MR and dynamic helical CT images obtained from 41 patients with 52 hypervascular HCCs (5-130 mm; mean, 27 mm) were retrospectively analyzed. MRI were obta...

متن کامل

Diffusion-Weighted MR Imaging before and after Contrast Enhancement with Superparamagnetic Iron Oxide for Assessment of Hepatic Metastasis

PURPOSE The purpose of our study was to validate diffusion-weighted MRI (DWI) before and after superparamagnetic iron oxide (SPIO) injection for assessment of hepatic metastases. MATERIALS AND METHODS Eighty-six hepatic metastases (size range, 0.3-4.7 cm; mean, 1.5 cm) verified pathologically or by follow-up imaging studies in 22 consecutive patients (17 men and 5 women; 44-83 years; mean age...

متن کامل

Evaluation of superparamagnetic iron oxide for MR imaging of liver injury: proton relaxation mechanisms and optimal MR imaging parameters.

PURPOSE To investigate the proton relaxation mechanisms and the optimal MR imaging parameters in superparamagnetic iron oxide (SPIO)-enhanced MR imaging of liver injury. METHODS A liver injury model was created in the rat using carbon tetrachloride. The T1 and T2 relaxation effects of SPIO in normal and injured liver were estimated by ex vivo relaxometry. In vivo laser confocal microscopy of ...

متن کامل

Superparamagnetic iron oxide-enhanced MR imaging of head and neck lymph nodes.

PURPOSE To compare findings on superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) images of the head and neck with those from resected lymph node specimens and to determine the effect of such imaging on surgical planning in patients with histopathologically proved squamous cell carcinoma of the head and neck. MATERIALS AND METHODS Thirty patients underwent MR imaging with no...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008