Anterior segment optical coherence tomography evaluation and comparison of main clear corneal incisions in microcoaxial and biaxial cataract surgery.

نویسندگان

  • Izzet Can
  • Hasan Ali Bayhan
  • Hale Celik
  • Başak Bostancı Ceran
چکیده

PURPOSE To use Fourier-domain anterior segment optical coherence tomography (AS-OCT)) to evaluate the main clear corneal incisions (CCIs) in microcoaxial and biaxial cataract surgery, the effects of incision enlargement, and the probable reasons for problematic healing. SETTING Atatürk Training and Research Hospital, 2nd Ophthalmology Department, Ankara, Turkey. DESIGN Cohort study. METHODS Eyes that had microcoaxial cataract surgery through a 1.8 mm CCI or biaxial cataract surgery through a 1.2 to 1.4 mm trapezoidal CCI were divided into 2 equal subgroups based on incision enlargement. All surgeries were completed by stromal hydration. Incisions were evaluated 1, 8, and 30 days postoperatively. RESULTS The CCIs in the microcoaxial group were longer, thinner, and more slanted than those in the biaxial group, with no statistical difference. The microcoaxial incisions had significantly more arcuate configuration at 1 day (P=.003); however, the configuration became linear in the following days in both groups. The endothelial gap rates were less and Descemet membrane detachment rates greater than reported in the literature. In eyes with enlarged CCIs, the endothelial gap rate was higher in the microcoaxial group and the Descemet membrane detachment rate was higher in the biaxial group (both P=.05). At 1 day, the intraocular pressure (IOP) was significantly lower in Descemet membrane detachment and endothelial gap cases (P=.006 and P<.001, respectively). CONCLUSIONS Although closure was reliable in both groups, the microcoaxial group had slightly fewer undesirable effects on the incision site. Low postoperative IOP seemed to be a significant factor in problematic healing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of corneal aberrations after biaxial microincision and microcoaxial cataract surgeries: a prospective study.

PURPOSE To compare the effects of biaxial microincision cataract surgery (B-MICS) and microcoaxial cataract surgery (C-MICS) techniques on corneal optical quality. MATERIALS AND METHODS In this prospective study, 40 eyes underwent B-MICS and 40 eyes C-MICS. Corneal aberrations were derived from conversion of the corneal elevation profile into corneal wavefront data with 6.0  mm aperture diame...

متن کامل

Profile of clear corneal cataract incisions demonstrated by ocular coherence tomography.

PURPOSE To examine the profile of clear corneal cataract incisions in the living eye using optical coherence tomography (OCT). SETTING Private practice, Eugene, Oregon, USA. METHODS The Zeiss Visante OCT anterior segment imaging system was used to study the profile of clear corneal cataract incisions, all in senior citizens. The OCT images of the operative eye were taken on the first postop...

متن کامل

Comparison of effect of nepafenac and diclofenac ophthalmic solutions on cornea, tear film, and ocular surface after cataract surgery: the results of a randomized trial

BACKGROUND The aim of this study was to compare the effects of nepafenac ophthalmic suspension 0.1% (Nevanac) and diclofenac sodium ophthalmic solution 0.1% (Diclod) on the cornea, tear film, and ocular surface after cataract surgery. METHODS A total of 60 eyes (60 patients) were selected for this study, with no ocular diseases other than cataract (scheduled for cataract surgery by one surgeo...

متن کامل

The Stromal Hydration of Clear Corneal Incisions

D r. Vasavada regularly performs stromal hydration, at both the clear corneal temporal incision and paracentesis, as part of his strategy for sealing the wound after cataract surgery. Further, he has found stromal hydration to be a useful adjunct in clear corneal cataract surgery, because it allows the adequate approximation of the anterior and posterior aspects of the corneal tunnel. Today, su...

متن کامل

Microcoaxial torsional cataract surgery 1.8 mm versus 2.2 mm: functional and morphological assessment.

BACKGROUND AND OBJECTIVE To compare functional and morphological outcomes of 1.8-mm versus 2.2-mm microincision coaxial cataract surgery (MCCS). PATIENTS AND METHODS Thirty eyes of 30 patients that underwent MCCS were randomized to two groups: 1.8-mm MCCS (group 1: 15 eyes) and 2.2-mm MCCS (group 2: 15 eyes). RESULTS There were no significant between-group differences in uncorrected visual ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2011