Acute hemodynamic changes of pressure-controlled inverse ratio ventilation in the adult respiratory distress syndrome. A transesophageal echocardiographic and Doppler study.

نویسندگان

  • J I Poelaert
  • C A Visser
  • J A Everaert
  • J J Koolen
  • F A Colardyn
چکیده

Twelve patients with the adult respiratory distress syndrome were included in this study and evaluated by transesophageal echocardiography and Doppler, assessing right and left ventricular intracardiac blood flow alterations with progressive increase of inspiration-to-expiration (I-E) ratios. Whereas midpulmonary artery flow parameters did not show any change, early left ventricular filling demonstrated a significant increase after switching the ventilatory mode from volume to pressure-controlled ventilation with 2:1 I-E ratio (end-inspiration: 39 +/- 26 cm with positive end-expiratory pressure [PEEP]-ventilation to 68 +/- 56 cm with pressure-controlled inverse-ratio ventilation, 2:1; p < 0.01; at end-expiration, from 67 +/- 21 cm with PEEP-ventilation to 83 +/- 36 cm with pressure-controlled ventilation 1:1; p < or = 0.05), resulting probably from different ventilatory flow and pressure curves. In the meanwhile, cardiac index demonstrated a significant augmentation (from 4.73 +/- 1.71 L/min.m2 to 5.56 +/- 1.66 L/min.m2; p < 0.05). Pressure-controlled inverse ratio ventilation results in both respiratory and hemodynamic advantages as is demonstrated by this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pressure-Controlled Inverse Ratio Ventilation during General Anesthesia for Open Abdominal Surgery Improves Postoperative Pulmonary Function

Background: Studies have shown that pressure-controlled ventilation improves alveolar gas distribution. And inverse ratio ventilation has advantages of improving oxygenation in acute respiratory distress syndrome (ARDS) patients. However, the effects that pressure-controlled inverse ration ventilation in patients undergoes endotracheal intubation general anesthesia have not been assessed. Objec...

متن کامل

Hemodynamic monitoring using a single-use indwelling transesophageal echocardiography probe in an unstable patient after open-heart surgery

BACKGROUND Hemodynamic monitoring is frequently needed in ventilated patients with unstable hemodynamics after open-heart surgery. Novel miniaturized single-use transesophageal echocardiographic probe has been scarcely used in this clinical setting. CASE PRESENTATION A patient who underwent a scheduled open-heart surgery developed a ventilator-associated pneumonia and was referred to the inte...

متن کامل

Cyclic changes in right ventricular output impedance during mechanical ventilation.

In a context such as acute respiratory distress syndrome, where optimum tidal volume and airway pressure levels are debated, the present study was designed to differentiate the right ventricular (RV) consequences of increasing lung volume from those secondary to increasing airway pressure during tidal ventilation. The study was conducted by combined two-dimensional echocardiographic and Doppler...

متن کامل

Early Nasal Intermittent Positive Pressure Ventilation (NIPPV) versus Nasal Continuous Positive Airway Pressure (NCPAP) for Respiratory Distress Syndrome (RDS) in Infants of 28-36 weeks gestational age: a Randomized Controlled Trial

Background: Early nasal continuous positive airway pressure (NCPAP) has emerged as a primary modality of respiratory support for preterm infants withrespiratory distress syndrome (RDS). However, 30%-40% of these newborns need subsequent mechanical ventilation. Nasal intermittent positive pressure ventilation (NIPPV) is a promising alternative to NCPAP, especially in po...

متن کامل

Increased blood pressure during inverse ratio ventilation in two patients with adult respiratory distress syndrome.

Inverse ratio ventilation (IRV) is increasingly used in the supportive treatment of patients with hypoxemic respiratory failure. A recent study suggests that IRV reduces cardiac output with minimal effect on mean arterial pressure. We report two cases in which IRV led to reproducible increases in mean arterial pressure. Concomitant hemodynamic measurements suggest that these responses occurred ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 104 1  شماره 

صفحات  -

تاریخ انتشار 1993